Quiznos 5989 Byram MS HVAC ProjectProject Quiznos 5989 Byram MS HVAC Calculations Tue Feb 7 15:40:33 CST 2006 There is no calculation for North & Shaded Glass There is no calculation for NorthEast and NorthWest Glass There is no calculation for East and West Glass There is no calculation for SouthEast and SouthWest Glass The Btuh Gain for 394 SqFt of South Single Pane Glass = 31520 There is no calculation for SkyLights There is no calculation for Windows in Doors The Btuh Gain for 394 SqFt of Mason Above Grade No Insulation Wall Number 1 = 4294.6 There is no calculation for Wall Number 2 There is no calculation for Wall Number 3 There is no calculation for Wall Number 4 The Btuh Gain for 1990 SqFt of Roof Only No Insulation; Ceiling Number 1 = 85570 There is no calculation for Ceiling Number 2 There is no calculation for Floor Number 1 There is no calculation for Floor Number 2 The Btuh Gain for 17 People = 170 There is no calculation for Motor HP There is no calculation for Ducts Out of Conditioned Spaces The Btuh Gain for 1990 SqFt of Area Lighting in a Retail Store = 7960 There is no calculation for Coffee Machines There is no calculation for Electric Food Warmers There is no calculation for Gas Food Warmers There is no calculation for Electric Fry Kettle There is no calculation for Gas Fry Kettle There is no calculation for Electric Griddle There is no calculation for Gas Griddle There is no calculation for Hair Dryer Helmets There is no calculation for 4-Slice Toaster There is no calculation for other appliances of known wattages There is no calculation for Outside Fresh Air #1 There is no calculation for Outside Fresh Air #2 There is no calculation for Outside Fresh Air #3 The Cafeteria or Fast Food Outside Fresh Air #4 = 480 cfm The Btuh Gain for Outside Fresh Air #4 = 14400 The Kitchen Outside Fresh Air #5 = 135 cfm The Btuh Gain for Outside Fresh Air #5 = 4050 There is no calculation for Outside Fresh Air #6 The Total Outside Fresh Air CFM = 615 This is in accordance with International Mechanical Code 2003 The Total BTUh Gain = 147964.6 The Total Tons of HVAC needed = 12.3303833333333