Fri Dec 23 10:52:13 CST 2005
There is no calculation for North & Shaded Glass
There is no
calculation for NorthEast and NorthWest Glass
There is no calculation for
East and West Glass
There is no calculation for SouthEast and SouthWest
Glass
There is no calculation for South Glass
There is no calculation
for SkyLights
There is no calculation for Windows in Doors
The Btuh Gain for 216 SqFt of Wood R-19 & 1/2" Gypsum Wall Number
1 = 367.2
The Btuh Gain for 108 SqFt of Wood R-19 & 1/2"
Gypsum Wall Number 2 = 183.6
The Btuh Gain for 1185 SqFt of
Wood R-19 & 1/2" Gypsum Wall Number 3 = 2014.5
The Btuh Gain for
411 SqFt of Wood R-19 & 1/2" Gypsum Wall Number 4 = 698.7
The Btuh Gain for 2537.14 SqFt of Ceiling and Roof Combo R-19; Ceiling
Number 1 = 12178.272
There is no calculation for Ceiling Number 2
There is no calculation for Floor Number 1
There is no calculation for
Floor Number 2
There is no calculation for People
There is no calculation for Motor HP
There is no calculation for Ducts Out of Conditioned Spaces
The Btuh Gain for 2537.14 SqFt of Area Lighting in a Retail Store = 10148.56
There is no calculation for Coffee Machines
There is no calculation for
Electric Food Warmers
There is no calculation for Gas Food Warmers
There
is no calculation for Electric Fry Kettle
There is no calculation for Gas
Fry Kettle
There is no calculation for Electric Griddle
There is no
calculation for Gas Griddle
There is no calculation for Hair Dryer Helmets
There is no calculation for 4-Slice Toaster
There is no calculation for
other appliances of known wattages
The Total Outside Fresh Air CFM = 3551.996
This is
in accordance with International Mechanical Code 2003
The Total BTUh Gain = 132150.712
The Total Tons of HVAC needed = 11.0125593333333