Project South Seas Chinese Dining Area HVAC HVAC Calculations

Thu Dec 22 13:55:05 CST 2005

There is no calculation for North & Shaded Glass
There is no calculation for NorthEast and NorthWest Glass
There is no calculation for East and West Glass
There is no calculation for SouthEast and SouthWest Glass
There is no calculation for South Glass
There is no calculation for SkyLights
There is no calculation for Windows in Doors

The Btuh Gain for 513 SqFt of Wood R-19 & 1/2" Gypsum Wall Number 1 = 872.1
The Btuh Gain for 959 SqFt of Wood R-19 & 1/2" Gypsum Wall Number 2 = 1630.3
The Btuh Gain for 348 SqFt of Wood R-19 & 1/2" Gypsum Wall Number 3 = 591.6
The Btuh Gain for 794 SqFt of Wood R-19 & 1/2" Gypsum Wall Number 4 = 1349.8

The Btuh Gain for 2160.64 SqFt of Ceiling and Roof Combo R-19; Ceiling Number 1 = 10371.072

There is no calculation for Ceiling Number 2

There is no calculation for Floor Number 1
There is no calculation for Floor Number 2

There is no calculation for People

There is no calculation for Motor HP

There is no calculation for Ducts Out of Conditioned Spaces

The Btuh Gain for 2160.64 SqFt of Area Lighting in a Retail Store = 8642.56

There is no calculation for Coffee Machines
There is no calculation for Electric Food Warmers
The wattage for 15 SqFt of Gas Food Warmers = 1800
There is no calculation for Electric Fry Kettle
The wattage for 12 SqFt of Gas Fry Kettle = 24000
There is no calculation for Electric Griddle
The wattage for 60 SqFt of Gas Griddle = 120000
There is no calculation for Hair Dryer Helmets
There is no calculation for 4-Slice Toaster
There is no calculation for other appliances of known wattages

The Dining Room Outside Fresh Air #1 = 3024.896 cfm
The Btuh Gain for Outside Fresh Air #1 = 90746.88
There is no calculation for Outside Fresh Air #2
There is no calculation for Outside Fresh Air #3
There is no calculation for Outside Fresh Air #4
There is no calculation for Outside Fresh Air #5
There is no calculation for Outside Fresh Air #6

The Total Outside Fresh Air CFM = 3024.896
This is in accordance with International Mechanical Code 2003

The Total BTUh Gain = 609924.312

The Total Tons of HVAC needed = 50.827026