<?xml version="1.0" encoding="windows-1252"?><SEC xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://si.ksc.nasa.gov/sidownloads/xml/specsintactSEC.xsd"><MTA NAME="SUBFORMAT" CONTENT="NEW"/><BRK/>
<HDR><AST/><BRK/>
USACE / NAVFAC / AFCESA / NASA                  UFGS-10 28 13 (July 2006)<BRK/>
                                                --------------------------<BRK/>
Preparing Activity:  <PRA>USACE</PRA>                      Superseding<BRK/>
                                                UFGS-10 28 13 (April 2006)<BRK/>
<BRK/>
<HL4>UNIFIED FACILITIES GUIDE SPECIFICATIONS</HL4><BRK/>
<BRK/>
<HL4>References are in agreement with UMRL dated January 2009</HL4><BRK/>
<AST/><BRK/></HDR>
<BRK/>
<SCN>SECTION 10 28 13</SCN><BRK/>
<BRK/>
<STL>TOILET ACCESSORIES</STL><BRK/>
<DTE>07/06</DTE><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This guide specification covers the requirements for <SCP>toilet accessories 
suitable for a wide variety of applications</SCP>.<BRK/>
<BRK/>
Edit this guide specification for project specific requirements by adding, deleting, 
or revising text.  For bracketed items, choose applicable items(s) or insert 
appropriate information.<BRK/>
<BRK/>
Remove information and requirements not required in respective project, whether 
or not brackets are present.<BRK/>
<BRK/>
Comments and suggestions on this guide specification are welcome and should 
be directed to the technical proponent of the specification.  A listing of <URL HREF="http://65.204.17.188/report/ufgs.html">technical 
proponents</URL>, including their organization designation and telephone number, is 
on the Internet.<BRK/>
<BRK/>
Recommended changes to a UFGS should be submitted as a  <URL HREF="http://65.204.17.188/projnet/cms/public.html">Criteria Change Request 
(CCR)</URL>.</NPR><BRK/>
<BRK/>
<NPR>This guide specification includes tailoring options for paper towel dispenser, 
combo towel dispenser/waste recept, and electric hand dryer.  Selection or deselection 
of a tailoring option will include or exclude that option in the section, but 
editing the resulting section to fit the project is still required.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<PRT><TTL>PART 1   GENERAL</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  For Army construction, buildings not excluded by the TI 800-01 Design 
Criteria will be accessible in accordance with 36 CFR, Part 1191, Americans 
with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities.</NPR><BRK/>
<BRK/>
<NPR>Drawings will indicate location, dimensions, elevations, schedules, details, 
and such other information as required to indicate the extent of the work.</NPR><BRK/>
<BRK/>
<NPR>Product selections shall be based on esthetic values and cost as related to 
project needs.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>1.1   REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This paragraph is used to list the publications cited in the text of 
the guide specification.  The publications are referred to in the text by basic 
designation only and listed in this paragraph by organization, designation, 
date, and title.<BRK/>
<BRK/>
Use the Reference Wizard's Check Reference feature when you add a RID outside 
of the Section's Reference Article to automatically place the reference in the 
Reference Article.  Also use the Reference Wizard's Check Reference feature 
to update the issue dates.<BRK/>
<BRK/>
References not used in the text will automatically be deleted from this section 
of the project specification when you choose to reconcile references in the 
publish print process.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The publications listed below form a part of this specification to the extent referenced.  The publications are 
referred to within the text by the basic designation only.</TXT><BRK/>
<BRK/>
<REF><ORG>ASTM INTERNATIONAL (ASTM)</ORG><BRK/><BRK/><RID>ASTM C 1036</RID><RTL>(2006) Standard Specification for Flat Glass</RTL><BRK/><BRK/></REF></SPT><SPT><TTL>1.2   SUBMITTALS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Review submittal description (SD) definitions in Section <SRF>01 33 00</SRF> SUBMITTAL 
PROCEDURES and edit the following list to reflect only the submittals required 
for the project.  Submittals should be kept to the minimum required for adequate 
quality control.<BRK/>
<BRK/>
A “G” following a submittal item indicates that the submittal requires Government 
approval.  Some submittals are already marked with a “G”.  Only delete an existing 
“G” if the submittal item is not complex and can be reviewed through the Contractor’s 
Quality Control system.  Only add a “G” if the submittal is sufficiently important 
or complex in context of the project.<BRK/>
<BRK/>
For submittals requiring Government approval on Army projects, a code of up 
to three characters within the submittal tags may be used following the "G" 
designation to indicate the approving authority.  Codes for Army projects using 
the Resident Management System (RMS) are:  "AE" for Architect-Engineer; "DO" 
for District Office (Engineering Division or other organization in the District 
Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project 
Office.  Codes following the "G" typically are not used for Navy, Air Force, 
and NASA projects.<BRK/>
<BRK/>
Choose the first bracketed item for Navy, Air Force and NASA projects, or choose 
the second bracketed item for Army projects.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Government approval is required for submittals with a "G" designation; submittals not having a "G" designation 
are for [Contractor Quality Control approval.][information only.  When used, a designation following the "G" 
designation identifies the office that will review the submittal for the Government.]  Submit the following in 
accordance with Section <SRF>01 33 00</SRF> SUBMITTAL PROCEDURES:</TXT><BRK/>
<BRK/>
<LST><SUB>SD-03 Product Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Finishes</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]<BRK/>
<SUB>Accessory Items</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  Manufacturer's descriptive data and catalog cuts indicating materials of construction, fasteners 
proposed for use for each type of wall construction, mounting instructions, operation instructions, 
and cleaning instructions.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-04 Samples</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Finishes</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]<BRK/>
<SUB>Accessory Items</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  One sample of each accessory proposed for use.  Incorporate approved samples into the finished 
work, provided they are identified and their locations noted.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-07 Certificates</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Accessory Items</SUB></ITM><BRK/>
<BRK/>
<ITM>  Certificate for each type of accessory specified, attesting that the items meet the specified 
requirements.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-10 Operation and Maintenance Data</SUB></LST><BRK/>
<BRK/>
<TAI OPT="ELECTRIC HAND DRYER"><ITM><SUB>Electric Hand Dryer</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  [Four] [_____] complete copies of maintenance instructions listing routine maintenance procedures 
and possible breakdowns.  Include repair instructions for simplified wiring and control diagrams 
and other information necessary for unit maintenance.</ITM></TAI><BRK/>
<BRK/></SPT>
<SPT><TTL>1.3   DELIVERY, STORAGE, AND HANDLING</TTL><BRK/>
<BRK/>
<TXT>Wrap toilet accessories for shipment and storage, then deliver to the jobsite in manufacturer's original packaging, 
and store in a clean, dry area protected from construction damage and vandalism.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.4   WARRANTY</TTL><BRK/>
<BRK/>
<TXT>Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.</TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 2   PRODUCTS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Only those accessories and finishes normally suitable for military construction 
are included in this guide specification.  When other accessories and finishes 
are required to meet the needs of the project, the specifier must add them.  
Maximum use should be made of recessed accessories in areas of hard usage.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>2.1   MANUFACTURED UNITS</TTL><BRK/>
<BRK/>
<TXT>Provide toilet accessories shall be provided where indicated in accordance with paragraph SCHEDULE.  Porcelain 
type, tile-wall accessories are specified in Section <SRF>09 30 00</SRF> CERAMIC TILE QUARRY TILE, AND PAVER TILE.  Provide 
each accessory item shall be complete with the necessary mounting plates of sturdy construction with corrosion 
resistant surface.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.1.1   Anchors and Fasteners</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Tamperproof fasteners will be specified for accessories which have exposed 
fasteners in areas used by neuropsychiatric patients or prisoners and where 
theft or vandalism would be a problem.  This guide specification places the 
responsibility with the Contractor for providing, subject to Government approval, 
fasteners and anchors of the type, size and number required to adequately secure 
the accessory items.  Specific requirements for critical or unusual applications 
may refer to details on the drawings, or the specifications may be expanded 
to include the necessary requirements.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide anchors and fasteners capable of developing a restraining force commensurate with the strength of the 
accessory to be mounted and suited for use with the supporting construction.  Provide [tamperproof design] [oval 
heads] exposed fasteners with finish to match the accessory.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.2   <SUB>Finishes</SUB></TTL><BRK/>
<BRK/>
<TXT>Except where noted otherwise, provide the following finishes on metal:</TXT><BRK/>
<TBL><THD><BRK/>
           Metal                              Finish<BRK/>
           _____                              ______<BRK/></THD>
<BRK/>
     Stainless steel                    No. 4 satin finish<BRK/>
<BRK/>
     Carbon steel, copper alloy,        Chromium plated, bright<BRK/>
     and brass<BRK/></TBL>
<BRK/></SPT>
</SPT><SPT><TTL>2.2   <SUB>ACCESSORY ITEMS</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Drawings will show location, widths and heights, and vertical height 
above finished floor, as required, for accessory items.</NPR><BRK/>
<BRK/>
<NPR>Only those accessory items to be used will be retained.  Identifying abbreviation 
in parentheses will be retained for those items to be used and shown on the 
drawings.  The various accessory items will generally be used in the following 
locations:</NPR><BRK/>
<BRK/>
<NPR>DCS:  Public toilets and toilets in nondomiciliary type buildings in accordance 
with the requirements of the using service.</NPR><BRK/>
<BRK/>
<TAI OPT="ELECTRIC HAND DRYER"><NPR>EHD:  Public toilets and toilets in nondomiciliary type buildings upon specific 
written request by the using service.</NPR></TAI><BRK/>
<BRK/>
<NPR>FTD:  Private bathrooms used by women.  Private/semi-private bathrooms in guest/transient 
quarters.  Limit to one per bathroom.</NPR><BRK/>
<BRK/>
<NPR>GB:  Bathrooms that will be used by handicapped or people in a weakened condition, 
such as in hospitals.  Vertical grab bars should be considered in private bathrooms 
where a soap and grab bar combination (SGR) accessory is not provided.  Forms 
and lengths will be shown on the drawings.</NPR><BRK/>
<BRK/>
<NPR>MC:  Private bathrooms where storage of personal items in the bathroom is desirable.  
Limit to one per bathroom.</NPR><BRK/>
<BRK/>
<NPR>MG:  Private bathrooms where a medicine cabinet is not provided, in general-use 
toilets, and hand washing areas.  Mirror 450 mm (18 inches) by 750 mm (30 inch) 
will be specified in Section 08 81 00  GLAZING.  Limit to not more than one 
per lavatory.  Adjustable tilt mirror will be provided in areas to be used by 
wheelchair handicapped.</NPR><BRK/>
<BRK/>
<NPR>MM:  Areas used by neuropsychiatric patients or prisoners and where vandalism 
would be a problem.  Limit to one per toilet in single lavatory installation.</NPR><BRK/>
<BRK/>
<TAI OPT="PAPER TOWEL DISPENSER"><NPR>PTD:  Public toilets and toilets in nondomiciliary type buildings in accordance 
with the requirements of the using service.  Limit to not more than one per 
two lavatories, except one per toilet in single lavatory installation.</NPR></TAI><BRK/>
<BRK/>
<TAI OPT="COMBO TOWEL DISOENSER/WASTE RECEPT"><NPR>PTDWR:  Public toilets and toilets in nondomiciliary type buildings in areas 
which have regularly scheduled waste removal.  Limit to one per two lavatories 
except one per toilet in single lavatory installation.</NPR></TAI><BRK/>
<BRK/>
<NPR>SND:  Public toilets and toilets in nondomiciliary type buildings used by women.  
Disposer will be mounted in the toilet compartments.  Each toilet compartment 
shall be accessible to a disposal unit.</NPR><BRK/>
<BRK/>
<NPR>SNTD:  Public toilets and toilets in nondomiciliary type buildings used by women.  
Use of recessed units will be considered for installations which are required 
to present an excellent appearance.  Limit to one per toilet.</NPR><BRK/>
<BRK/>
<NPR>SC &amp; SCR:  Installations with combination bathtub and shower SCR units which 
include rails and curtains.  One per shower-tub installation and one per individual 
shower installation.</NPR><BRK/>
<BRK/>
<NPR>SD:  Public toilets and toilets in nondomiciliary type buildings unless included 
with paper towel dispenser.  Limit to one per lavatory.</NPR><BRK/>
<BRK/>
<NPR>SH:  Private toilets with lavatory unless soap dispenser is specified.  Limit 
to one per private toilet.</NPR><BRK/>
<BRK/>
<NPR>SMHD:  Troop facilities and other areas subject to rough usage.  Installation 
will be detailed on the drawings.</NPR><BRK/>
<BRK/>
<NPR>SMLD:  Private bathrooms where a glass shelf or medicine cabinet is not provided.</NPR><BRK/>
<BRK/>
<NPR>SGR:  Installations with bathtub or shower.  Limit to one per bathtub or shower-tub 
installation and one per separate showerhead.</NPR><BRK/>
<BRK/>
<NPR>TB:  Private bathrooms.  Limit to two per bathroom.  For safety purposes in 
wet areas consider using a horizontal grab bar in lieu of towel bar.</NPR><BRK/>
<BRK/>
<NPR>TSCD:  Public toilets and toilets in nondomiciliary type buildings in accordance 
with the requirements of the using service.</NPR><BRK/>
<BRK/>
<NPR>TP:  Private bathrooms where a shower is provided in lieu of a bathtub.  Limit 
to one per bathroom.</NPR><BRK/>
<BRK/>
<NPR>TTD:  All toilet areas.  Limit to one per water closet.</NPR><BRK/>
<BRK/>
<NPR>TTH:  Private bathrooms.  Limit to one per lavatory.</NPR><BRK/>
<BRK/>
<NPR>WR:  Public toilets and toilets in nondomiciliary type buildings when requested 
by the using service.  Limit to not more than one per two paper towel dispensers.  
Use of recessed combination units will be considered for installations which 
have frequent scheduled trash removal service.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Conform to the requirements for accessory items specified below.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.1   Facial Tissue Dispenser (FTD)</TTL><BRK/>
<BRK/>
<TXT>Provide [surface] [recessed] mounted facial tissue dispenser, Type 304 stainless steel face, [satin finish] [bright 
polished finish].  Secure face of recessed dispenser by friction with suitable spring steel clips.  Provide a 
minimum capacity of [150] [200] [300] two-ply tissues for dispenser.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.2   Grab Bar (GB)</TTL><BRK/>
<BRK/>
<TXT>Provide an 18 gauge, <MET>32 mm</MET><ENG> 1-1/4 inch</ENG> grab bar OD Type 304 stainless steel.  Provide form and length for grab 
bar as indicated.  Provide [concealed] [exposed] mounting flange.  Provide grab with [satin finish] [peened non-slip 
surface].  Furnish installed bars capable of withstanding a<MET> 2.225 kN</MET><ENG> 500 pound</ENG> vertical load without coming loose 
from the fastenings and without obvious permanent deformation.  Allow<MET> 38 mm</MET><ENG> 1-1/2 inch</ENG> space between wall and 
grab bar.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.3   Medicine Cabinet (MC)</TTL><BRK/>
<BRK/>
<TXT>Construct medicine cabinet with cold-rolled carbon steel sheet of minimum<MET> 0.76 mm</MET><ENG> 0.03 inch</ENG> thickness, formed 
from a single sheet of steel or mechanically formed and spot welded.  Provide width, height and depth of cabinet 
in accordance with paragraph SCHEDULE.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.3.1   Sliding Door Cabinet, Class 1</TTL><BRK/>
<BRK/>
<TXT>Provide [surface mounted vanity] [recessed cabinet] sliding door cabinet assembly with design and lighting arrangement 
as indicated.  Provide a minimum of 2 shelves per cabinet.  Provide [a wide] [a narrow] [no] frame mirror.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.3.2   Swinging Door Cabinet, Class 2</TTL><BRK/>
<BRK/>
<TXT>Furnish swinging door cabinet assembly, including the lighting arrangement, as indicated.  Provide [surface] 
[recess] mounted assembly.  Locate cabinet centrally behind the door with a minimum of two shelves.  Provide 
stainless steel or carbon steel door hinges.  Provide permanent type magnets used in door catches.  Provide doors 
[with] [without] a mirror.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.4   Mirrors, Glass (MG)</TTL><BRK/>
<BRK/>
<TXT>Provide Type I transparent flat type, Class 1-clear glass for mirrors.  Glazing Quality q1<MET> 6 mm</MET><ENG> 1/4 inch</ENG> thick 
conforming to <RID>ASTM C 1036</RID>.  Coat glass on one surface with silver coating, copper protective coating, and mirror 
backing paint.  Provide highly adhesive pure silver coating of a thickness which provides reflectivity of 83 
percent or more of incident light when viewed through<MET> 6 mm</MET><ENG> 1/4 inch</ENG> thick glass, free of pinholes or other defects.  
Provide copper protective coating with pure bright reflective copper, homogeneous without sludge, pinholes or 
other defects, of proper thickness to prevent "adhesion pull" by mirror backing paint.  Provide mirror backing 
paint with two coats of special scratch and abrasion-resistant paint and baked in uniform thickness to provide 
a protection for silver and copper coatings which will permit normal cutting and edge fabrication.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.5   Mirror, Metal (MM)</TTL><BRK/>
<BRK/>
<TXT>Provide a brightly polished stainless steel metal mirror of<MET>0.94 mm</MET><ENG> 0.037 inch</ENG> minimum thickness, edges turned 
back<MET> 6 mm</MET><ENG> 1/4 inch</ENG> and recess fitted with tempered hardboard backing, and theft-proof fasteners.  Provide size 
in accordance with paragraph SCHEDULE.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.6   Mirror, Tilt (MT)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Mounting height of mirror shall be shown on the drawings.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide surface mounted tilt mirror with full visibility for persons in a wheelchair.  Furnish [adjustable] [fixed] 
tilt mirror, extending at least<MET> 100 mm</MET><ENG> 4 inch</ENG> from the wall at the top and tapering to<MET> 25 mm</MET><ENG> 1 inch</ENG> at the bottom.  
Provide size in accordance with [paragraph SCHEDULE] [the drawings] [_____].  Conform to <RID>ASTM C 1036</RID> and paragraph 
Glass Mirrors.</TXT><BRK/>
<BRK/></SPT>
<TAI OPT="PAPER TOWEL DISPENSER"><SPT><TTL>2.2.7   Paper Towel Dispenser (PTD)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  A tumbler key lock is the standard locking mechanism for manufacturers 
and push button or twist-type locks are normally a specialty, extra-cost item, 
if available.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide [_____] paper towel dispenser constructed of a minimum [22 gauge carbon steel][<MET>0.7 mm</MET><ENG>0.03 inch</ENG> Type 304 
stainless steel], [surface][recessed] mounted.  Provide a towel compartment and a [mirror door][ and][ liquid 
soap dispenser] for each dispenser.  Furnish [tumbler key lock][concealed tumbler key lock] locking mechanism.</TXT><BRK/>
<BRK/></SPT>
</TAI><TAI OPT="COMBO TOWEL DISOENSER/WASTE RECEPT"><SPT><TTL>2.2.8   Combination Paper Towel Dispenser/Waste Receptacle (PTDWR)</TTL><BRK/>
<BRK/>
<TXT>Provide [recessed][semi-recessed] dispenser/receptacle with a capacity of [400][600][_____] sheets of C-fold, 
single-fold, or quarter-fold towel.  Design waste receptacle to be locked in unit and removable for service.  
Provide tumbler key locking mechanism.  Provide waste receptacle capacity of<MET> [45][68][_____] L</MET><ENG> [12][18][_____] 
gallons</ENG>.  Fabricate a minimum<MET> 0.7 mm</MET><ENG> 0.03 inch</ENG> stainless steel welded construction unit with all exposed surfaces 
having a satin finish.  Provide waste receptacle that accepts reusable liner standard for unit manufacturer.</TXT><BRK/>
<BRK/></SPT>
</TAI><SPT><TTL>2.2.9   Sanitary Napkin Disposer (SND)</TTL><BRK/>
<BRK/>
<TXT>Construct a Type 304 stainless steel sanitary napkin disposal with removable leak-proof receptacle for disposable 
liners.  Provide [fifty] [_____] disposable liners of the type standard with the manufacturer.  Retain receptacle 
in cabinet by tumbler lock.  Provide disposer with a door for inserting disposed napkins, [recessed] [partition 
mounted, double access] [surface mounted].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.10   Sanitary Napkin and Tampon Dispenser (SNTD)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Specify sanitary napkin and tampon dispensers only when they are specifically 
requested, in writing, by the Using Agency.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide sanitary napkin and tampon dispenser [surface mounted] [recessed].  Dispenser, including door of Type 
304 stainless steel that dispense both napkins and tampons with a minimum capacity of 20 each.  Furnish dispensing 
mechanism for [complimentary] [coin] operation.  Provide coin mechanisms with minimum denominations of 10 cents, 
25 cents, 50 cents, [_____] [free].  Hang doors with a full-length corrosion-resistant steel piano hinge and 
secure with a tumbler lock.  Provide keys for coin box different from the door keys.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.11   Shower Curtain (SC)</TTL><BRK/>
<BRK/>
<TXT>Provide [_____] shower curtain, size to suit conditions.  Provide anti-bacterial nylon/vinyl fabric curtain.  
Furnish [_____] color [as shown in Section <SRF>09 06 90</SRF> COLOR SCHEDULE].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.12   Shower Curtain Rods (SCR)</TTL><BRK/>
<BRK/>
<TXT>Provide Type 304 stainless steel shower curtain rods<MET> 32 mm</MET><ENG> 1-1/4 inch</ENG> OD by<MET> 1.24 mm</MET><ENG> 0.049 inch</ENG> minimum [straight] 
[bent as required] to meet installation conditions.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.13   Soap Dispenser (SD)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Powdered soap dispenser should be included for a shop or industrial area.  
Edit to meet project requirements.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide soap dispenser [surface mounted, liquid type consisting of a vertical Type 304 stainless steel tank with 
holding capacity of<MET> 1.2 L</MET><ENG> 40 fluid ounces</ENG> with a corrosion-resistant all-purpose valve that dispenses liquid 
soaps, lotions, detergents and antiseptic soaps.] [surface mounted, powder type constructed of stainless steel 
or chromium plated zinc die casting, containing a swap feed mechanism and an agitator designed to break up powdered 
soap, with a minimum capacity of<MET> 0.94 L</MET><ENG> 32 ounces</ENG>.] [lavatory mounted, liquid type consisting of a polyethylene 
tank with a minimum<MET> 0.94 L</MET><ENG> 32 fluid ounces</ENG> holding capacity and a [<MET>100 mm</MET><ENG> 4 inch</ENG>] [<MET>150 mm</MET><ENG> 6 inch</ENG>] spout length.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.14   Soap Holder (SH)</TTL><BRK/>
<BRK/>
<TXT>Provide [surface mounted] [recessed] Type 304 stainless steel soap holder.  Provide stainless steel separate 
supports.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.15   Shelf, Metal, Heavy Duty (SMHD)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Where rough usage is anticipated, shelf support brackets and through-bolting 
of accessories should be required and indicated on the project drawings.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Furnish a minimum 18 gauge stainless steel heavy duty metal shelf with hemmed edges.  Provide shelves over<MET> 750 
mm</MET><ENG> 30 inch</ENG> with intermediate supports.  Provide minimum of 16 gauge supports, welded to the shelf, and spaced 
no more than<MET> 750 mm</MET><ENG> 30 inch</ENG> apart.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.16   Shelf, Metal, Light Duty (SMLD)</TTL><BRK/>
<BRK/>
<TXT>Support light duty metal shelf between brackets or on brackets.  Purpose of brackets is to prevent lateral movement 
of the shelf.  Furnish [<MET>450 mm</MET><ENG> 18 inch</ENG>] [<MET>600 mm</MET><ENG> 24 inch</ENG>] long shelf.  Provide stainless steel shelf and brackets.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.17   Soap and Grab Bar Combination, Recessed (SGR)</TTL><BRK/>
<BRK/>
<TXT>Provide recessed type, Type 304 stainless steel soap and grab bar combination [bright polished finish] [satin 
finish].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.18   Towel Bar (TB)</TTL><BRK/>
<BRK/>
<TXT>Provide stainless steel towel bar with a minimum thickness of<MET> 0.38 mm</MET><ENG> 0.015 inch</ENG>.  Provide minimum<MET> 19 mm</MET><ENG> 3/4 
inch</ENG> diameter bar, or<MET> 16 mm</MET><ENG> 5/8 inch</ENG> square.  Provide [bright polish] [satin] finish.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.19   Towel Pin (TP)</TTL><BRK/>
<BRK/>
<TXT>Provide towel pin with concealed wall fastenings, and a pin integral with or permanently fastened to wall flange 
with maximum projection of<MET> 100 mm</MET><ENG> 4 inch</ENG>.  Provide [bright polish] [satin] finish.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.20   Toilet Tissue Dispenser (TTD)</TTL><BRK/>
<BRK/>
<TXT>Furnish [Type II - surface mounted] [Type III - recess mounted] toilet tissue holder with two rolls of standard 
tissue [mounted horizontally] [stacked vertically].  Provide [carbon steel, bright chromium plated] [stainless 
steel, satin] finish cabinet.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.21   Toilet Tissue Dispenser, Jumbo (TTDJ)</TTL><BRK/>
<BRK/>
<TXT>Provide surface mounted toilet tissue dispenser with 2 rolls of jumbo tissue.  Fabricate cabinet of [Type 304, 
18 gauge stainless steel with Type 304, 20 gauge stainless steel door] [high-impact plastic body and transparent 
plastic front cover].  Provide cover with key lock.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.22   Toothbrush and Tumbler Holder (TTH)</TTL><BRK/>
<BRK/>
<TXT>Provide stainless steel, surface mounted toothbrush and tumbler holder.  Furnish holder to hold a minimum of 
four toothbrushes in a vertical position.  Provide<MET> 57 plus or minus 3 mm</MET><ENG> 2-1/4 plus or minus 1/8 inch</ENG> in diameter 
size of hole for securing tumbler.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.23   Waste Receptacle (WR)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Locks are typically provided on recessed and semi-recessed receptacles.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide Type 304 stainless steel waste receptacle, designed for [recessed] [surface] mounting.  Provide reuseable 
liner, of the type standard with the receptacle manufacturer.  Provide a minimum [_____]<MET> cubic meters</MET><ENG> cubic feet</ENG>
 capacity.  Provide receptacles with push doors and doors for access to the waste compartment with continuous 
hinges.  Furnish [tumbler key lock] [_____] locking mechanism.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.24   Toilet Seat Cover Dispenser (TSCD)</TTL><BRK/>
<BRK/>
<TXT>Provide Type 304 stainless steel with [recessed mounted] [surface mounted] toilet seat cover dispensers.  Provide 
dispenser with a minimum capacity of 500 seat covers.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.25   Toilet Seat Cover/Tissue Dispenser/Waste Receptacle (TSCTDWR)</TTL><BRK/>
<BRK/>
<TXT>Provide stainless steel and [partition mounted] [recessed mounted] [surface mounted] toilet seat cover, tissue 
dispenser, and waste receptacle combination.  Provide a minimum of 500 [seat covers] [seat covers per side] and 
[2] [4 (2 per side)] standard tissue rolls for each dispenser.  Provide a waste receptacle of the reuseable liner 
of type standard with the receptacle manufacturer.  Provide receptacle with [_____]<MET> cubic meters</MET><ENG> cubic feet</ENG> capacity.  
Furnish [tumbler key lock] [_____] locking mechanism.</TXT><BRK/>
<BRK/></SPT>
<TAI OPT="ELECTRIC HAND DRYER"><SPT><TTL>2.2.26   <SUB>Electric Hand Dryer</SUB> (EHD)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Consider the use of electric hand driers in public toilet areas that 
may not receive daily custodian care and in areas where cleanliness is an issue 
such as food preparation, dining facilities, and hospitals.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide wall mount and electric hand dryer designed to operate at 110/125 volts, 60 cycle, single phase alternating 
current with a heating element core rating of a maximum 2100 watts.  Provide dryer housing of single piece construction 
and of [white porcelain enamel] [chrome plated steel] [baked electrostatically applied epoxy] [_____].</TXT><BRK/>
<BRK/></SPT>
</TAI><SPT><TTL>2.2.27   Diaper Changing Station (DCS)</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Omit requirement for integral dispenser for sanitary liners if not required.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide [recess mount] [surface mounted] diaper changing station fabricated of high impact plastic with no sharp 
edges.  Provide fold down platform concave to the child's shape, equipped with nylon and velcro safety straps 
and engineered to withstand a minimum static load of [<MET>155 kg</MET><ENG> 340 lb</ENG>] [<MET>113 kg</MET><ENG> 250 lb</ENG>].  Provide an integral dispenser 
for sanitary liners for each unit.  Provide pictorial for universal use of safety graphics.  Furnish color [_____] 
[as shown in Section <SRF>09 06 90</SRF> COLOR SCHEDULE].</TXT><BRK/>
<BRK/></SPT>
</SPT></PRT><PRT><TTL>PART 3   EXECUTION</TTL><BRK/>
<BRK/>
<SPT><TTL>3.1   INSTALLATION</TTL><BRK/>
<BRK/>
<TXT>Provide the same finish for the surfaces of fastening devices exposed after installation as the attached accessory.  
Provide oval exposed screw heads.  Install accessories at the location and height indicated.  Protect exposed 
surfaces of accessories with strippable plastic or by other means until the installation is accepted.  After 
acceptance of accessories, remove and dispose of strippable plastic protection.  Coordinate accessory manufacturer's 
mounting details with other trades as their work progresses.  [Use sealants for brackets, plates, anchoring devices 
and similar items in showers (a silicone or polysulphide sealant) as they are set to provide a watertight installation.]  
After installation, thoroughly clean exposed surfaces and restore damaged work to its original condition or replace 
with new work.</TXT><BRK/>
<BRK/>
<SPT><TTL>3.1.1   Recessed Accessories</TTL><BRK/>
<BRK/>
<TXT>Fasten accessories with wood screws to studs, blocking or rough frame in wood construction.  Set anchors in mortar 
in masonry construction.  Fasten to metal studs or framing with sheet metal screws in metal construction.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.1.2   Surface Mounted Accessories</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Shelf support brackets and through-bolting of accessories should be required 
and indicated on the project drawings when rough usage of accessories is anticipated.  
Attachment by through-bolting should be indicated for shelf brackets and mirrors.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Mount on concealed backplates, unless specified otherwise.  Conceal fasteners on accessories without backplates.  
Install accessories with sheet metal screws or wood screws in lead-lined braided jute, teflon or neoprene sleeves, 
or lead expansion shields, or with toggle bolts or other approved fasteners as required by the construction.  
Install backplates in the same manner, or provide with lugs or anchors set in mortar, as required by the construction.  
Fasten accessories mounted on gypsum board and plaster walls without solid backing into the metal or wood studs 
or to solid wood blocking secured between wood studs, or to metal backplates secured to metal studs.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>3.2   CLEANING</TTL><BRK/>
<BRK/>
<TXT>Clean material in accordance with manufacturer's recommendations.  Do mot use alkaline or abrasive agents.  Take 
precautions to avoid scratching or marring exposed surfaces.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.3   SCHEDULE</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  A schedule of the accessories required will be added.  Format for the 
schedule may be modified to suit local preference.  In some cases it may be 
adequate to simply show the locations on the drawings or to specify locations 
in the specification text.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TBL><THD><BRK/>
<HL4>Accessories Required</HL4><BRK/>
<BRK/>
             Room<BRK/>
             or<BRK/>
             Space       MG     PTD     SMLD     SD      SH       TTD<BRK/>
             _____      ______________________________________________<BRK/></THD>
<BRK/>
            [_____]   [_____] [_____] [_____]  [_____] [_____]  [_____]<BRK/></TBL>
<BRK/></SPT>
</PRT>     <END/><BRK/></SEC>