<?xml version="1.0" encoding="windows-1252"?><SEC xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://si.ksc.nasa.gov/sidownloads/xml/specsintactSEC.xsd"><MTA NAME="SUBFORMAT" CONTENT="NEW"/><HDR><AST/><BRK/>
USACE / NAVFAC / AFCESA / NASA      UFGS-10 56 13 (April 2006)<BRK/>
                                    ------------------------------<BRK/>
Preparing Activity:  <PRA>NAVFAC</PRA>         Replace without change<BRK/>
                                    UFGS-10675 (August 2004)<BRK/>
<BRK/>
<HL4>UNIFIED FACILITIES GUIDE SPECIFICATIONS</HL4><BRK/>
<BRK/>
<HL4>References are in agreement with UMRL dated January 2009</HL4><BRK/>
<AST/><BRK/></HDR>
<BRK/>
<SCN>SECTION 10 56 13</SCN><BRK/>
<BRK/>
<STL>STEEL SHELVING</STL><BRK/>
<DTE>04/06</DTE><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This guide specification covers the requirements for <SCP>hand loaded steel 
shelving units</SCP>.<BRK/>
<BRK/>
Edit this guide specification for project specific requirements by adding, deleting, 
or revising text.  For bracketed items, choose applicable items(s) or insert 
appropriate information.<BRK/>
<BRK/>
Remove information and requirements not required in respective project, whether 
or not brackets are present.<BRK/>
<BRK/>
Comments and suggestions on this guide specification are welcome and should 
be directed to the technical proponent of the specification.  A listing of <URL HREF="http://65.204.17.188/report/ufgs.html">technical 
proponents</URL>, including their organization designation and telephone number, is 
on the Internet.<BRK/>
<BRK/>
Recommended changes to a UFGS should be submitted as a  <URL HREF="http://65.204.17.188/projnet/cms/public.html">Criteria Change Request 
(CCR)</URL>.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Show the following information on the project drawings.</NPR><BRK/>
<BRK/>
<NPR>1.  Location, length, and type of shelving units.</NPR><BRK/>
<BRK/>
<NPR>2.  Aisle layout</NPR><BRK/>
<BRK/>
<NPR>3.  Loading and accessories</NPR><BRK/>
<BRK/>
<NPR>4.  Mounting and anchorage requirements or details.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<PRT><TTL>PART 1   GENERAL</TTL><BRK/>
<BRK/>
<SPT><TTL>1.1   REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This paragraph is used to list the publications cited in the text of 
the guide specification. The publications are referred to in the text by basic 
designation only and listed in this paragraph by organization, designation, 
date, and title.<BRK/>
 <BRK/>
Use the Reference Wizard's Check Reference feature when you add a RID outside 
of the Section's Reference Article to automatically place the reference in the 
Reference Article.  Also use the Reference Wizard's Check Reference feature 
to update the issue dates.<BRK/>
 <BRK/>
References not used in the text will automatically be deleted from this section 
of the project specification when you choose to reconcile references in the 
publish print process.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The publications listed below form a part of this specification to the extent referenced.  The publications are 
referred to within the text by the basic designation only.</TXT><BRK/>
<BRK/>
<REF><ORG>ASTM INTERNATIONAL (ASTM)</ORG><BRK/><BRK/><RID>ASTM D 2794</RID><RTL>(1993; R 2004) Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)</RTL><BRK/><BRK/><RID>ASTM D 3359</RID><RTL>(2008) Measuring Adhesion by Tape Test</RTL><BRK/><BRK/><RID>ASTM D 522</RID><RTL>(1993a; R 2008) Mandrel Bend Test of Attached Organic Coatings</RTL><BRK/><BRK/></REF><REF><ORG>MATERIAL HANDLING INDUSTRY OF AMERICA INC (MHIA)</ORG><BRK/><BRK/><RID>MHI MH28.1</RID><RTL>(1997) Specification: Industrial Steel Grade Shelving</RTL><BRK/><BRK/></REF></SPT><SPT><TTL>1.2   DEFINITIONS</TTL><BRK/>
<BRK/>
<TXT>For the purposes of this specification the shelf category, "medium weight," "heavy weight," will be as follows.  
Load is given per shelf in<MET> kilograms</MET><ENG> pounds</ENG> for evenly distributed load.  This does not limit the shelf size, 
only the shelving category.</TXT><BRK/>
<MET><TBL><THD><BRK/>
<HL4>Minimum Evenly Distributed Load Per Shelf in Kilograms</HL4><BRK/>
<BRK/>
                               Type                Type<BRK/>
     Shelf Size              Medium Duty         Heavy Duty<BRK/></THD>
<BRK/>
     450 by 900 mm              320                  590<BRK/>
<BRK/>
     450 by 1200 mm             230                  410<BRK/></TBL>
</MET><ENG><TBL><THD><BRK/>
<HL4>Minimum Evenly Distributed Load Per Shelf in Pounds</HL4><BRK/>
<BRK/>
                                Type                Type<BRK/>
     Shelf Size              Medium Duty         Heavy Duty<BRK/></THD>
<BRK/>
     18 by 36 in.               700                 1300<BRK/>
<BRK/>
     18 by 48 in.               500                  900<BRK/></TBL>
</ENG><BRK/></SPT>
<SPT><TTL>1.3   SUBMITTALS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL 
PROCEDURES and edit the following list to reflect only the submittals required 
for the project.  Submittals should be kept to the minimum required for adequate 
quality control.<BRK/>
<BRK/>
A “G” following a submittal item indicates that the submittal requires Government 
approval.  Some submittals are already marked with a “G”.  Only delete an existing 
“G” if the submittal item is not complex and can be reviewed through the Contractor’s 
Quality Control system.  Only add a “G” if the submittal is sufficiently important 
or complex in context of the project.<BRK/>
<BRK/>
For submittals requiring Government approval on Army projects, a code of up 
to three characters within the submittal tags may be used following the "G" 
designation to indicate the approving authority.  Codes for Army projects using 
the Resident Management System (RMS) are:  "AE" for Architect-Engineer; "DO" 
for District Office (Engineering Division or other organization in the District 
Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project 
Office.  Codes following the "G" typically are not used for Navy,  Air Force, 
and NASA projects.<BRK/>
<BRK/>
Choose the first bracketed item for Navy, Air Force and NASA projects, or choose 
the second bracketed item for Army projects.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Government approval is required for submittals with a "G" designation; submittals not having a "G" designation 
are [for Contractor Quality Control approval.][for information only.  When used, a designation following the 
"G" designation identifies the office that will review the submittal for the Government.]  The following shall 
be submitted in accordance with Section <SRF>01 33 00</SRF> SUBMITTAL PROCEDURES:</TXT><BRK/>
<BRK/>
<LST><SUB>SD-01 Preconstruction Submittals</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Shelving Units</SUB></ITM><BRK/>
<BRK/>
<LST><SUB>SD-03 Product Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Shelving Units</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Accessories</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Installation instructions</SUB></ITM><BRK/>
<BRK/>
<LST><SUB>SD-04 Samples</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Finish</SUB></ITM><BRK/>
<BRK/>
<LST><SUB>SD-06 Test Reports</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Shelving Units</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Finish</SUB></ITM><BRK/>
<BRK/></SPT>
<SPT><TTL>1.4   DELIVERY, STORAGE, AND HANDLING</TTL><BRK/>
<BRK/>
<TXT>Deliver materials in original packages, containers or bundles bearing the brand name and identification  of the 
manufacturer.  Store inside under cover.  Protect surfaces from damage.</TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 2   PRODUCTS</TTL><BRK/>
<BRK/>
<SPT><TTL>2.1   MANUFACTURED UNITS</TTL><BRK/>
<BRK/>
<TXT><RID>MHI MH28.1</RID>.  Provide <SUB>shelving units</SUB> [indicated] [scheduled].  Provide shelving units designed for full dead and 
live load, designated [medium duty] [heavy duty].  [Provide units with base plates for floor anchorage indicated.]  
[Provide wall connections for units over<MET> 2500 mm</MET><ENG> 8 feet 3 inches</ENG> to top shelf.]  [Provide floor and wall anchorages 
for units in Seismic Zone 3 or 4.  Provide door and drawer earthquake stops.] [Provide wall connections for drawer 
units if necessary.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2   <SUB>ACCESSORIES</SUB></TTL><BRK/>
<BRK/>
<ITM INDENT="-0.33">a.  Drawers,<MET> 180 kg</MET><ENG> 400 pound</ENG> capacity, and mounting brackets</ITM><BRK/>
<BRK/>
<ITM INDENT="-0.33">b.  Partitions and dividers</ITM><BRK/>
<BRK/>
<ITM INDENT="-0.33">c.  Label holder<MET> [56 by 20 mm] [75 by 125 mm]</MET><ENG> [2 1/4 by 3/4 inches] [3 by 5 inches]</ENG>.</ITM><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3   <SUB>FINISH</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Specify special finish only if the conditions of use are particularly 
harsh.  Any finish other than the manufacturer's standard will be very expensive.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide the shelving units in the manufacturer's standard colors [as indicated] [as chosen by the Contracting 
Officer].  Clean metal by multiple stage phosphatizing and sealing process, for rust resistance and paint adhesion.  
Provide electrostatically applied enamel finish coats, baked hard for a minimum of 30 minutes at<MET> 149 degrees 
C</MET><ENG> 300 degrees F</ENG>.  [Provide special finish meeting the flexibility, adhesion, and impact standards below.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4   SOURCE QUALITY CONTROL</TTL><BRK/>
<BRK/>
<ITM INDENT="-0.33">a.  <RID>MHI MH28.1</RID>, for tests of <TST>shelf capacity</TST>, lateral stability and shelf connections.</ITM><BRK/>
<BRK/>
<ITM INDENT="-0.33">[b.  <TST>Finish flexibility</TST>, <RID>ASTM D 522</RID>, Method A,<MET> 3 mm</MET><ENG> 1/8 inch</ENG> diameter, 180 degree bend, no evidence 
of fracturing to the naked eye.]</ITM><BRK/>
<BRK/>
<ITM INDENT="-0.33">[c.  <TST>Finish adhesion</TST>, <RID>ASTM D 3359</RID>, Method B.  There shall be no film removed by tape applied 
to 11 parallel cuts space<MET> 3 mm</MET><ENG> 1/8 inch</ENG> apart plus 11 similar cuts at right angles.]</ITM><BRK/>
<BRK/>
<ITM INDENT="-0.33">[d.  <TST>Impact resistant finish</TST>, <RID>ASTM D 2794</RID>, no loss of adhesion after direct and reverse impact 
equal to 1.5 times metal thickness in mm, expressed in<MET> N.m</MET><ENG> inch pounds</ENG>.]</ITM><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 3   EXECUTION</TTL><BRK/>
<BRK/>
<SPT><TTL>3.1   EXAMINATION</TTL><BRK/>
<BRK/>
<TXT>Before installation, examine shelving units for dents and scratches.  Replace damaged shelving.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.2   INSTALLATION</TTL><BRK/>
<BRK/>
<TXT>Install shelving according to manufacturer's <SUB>installation instructions</SUB>.  [Make wall and floor connections as 
indicated.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.3   PROTECTION</TTL><BRK/>
<BRK/>
<TXT>Cover and protect shelving from damage during the completion of construction.  Remove prior to acceptance of 
project.</TXT><BRK/>
<BRK/></SPT>
<SPT>[<TTL>3.4   SCHEDULE</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Put on contract drawings by preference.</NPR><BRK/>
<AST/><BRK/></NTE>
<TBL><THD><BRK/>
<HL4>SHELVING</HL4><BRK/>
<BRK/>
   Type       Width     Depth     Number     Height   Accessories   Room<BRK/>
                                 of Shelves<BRK/></THD>
<BRK/>
   [_____]    [_____]  [_____]   [_____]     [_____]   [_____]      [_____]</TBL><BRK/>
<BRK/>
]</SPT></PRT>    <END/><BRK/></SEC>