<?xml version="1.0" encoding="windows-1252"?><SEC xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://si.ksc.nasa.gov/sidownloads/xml/specsintactSEC.xsd"><MTA NAME="SUBFORMAT" CONTENT="NEW"/><HDR><AST/><BRK/>
USACE / NAVFAC / AFCESA              UFGS-05 12 00 (October 2007)<BRK/>
                                     -------------------------------<BRK/>
Preparing Activity:  <PRA>NAVFAC</PRA>          Superseding <BRK/>
                                     UFGS-05 12 00 (July 2006)<BRK/>
<BRK/>
<HL4>UNIFIED FACILITIES GUIDE SPECIFICATIONS</HL4><BRK/>
<BRK/>
<HL4>References are in agreement with UMRL dated January 2009</HL4><BRK/>
<AST/><BRK/></HDR>
<BRK/>
<SCN>SECTION 05 12 00</SCN><BRK/>
<BRK/>
<STL>STRUCTURAL STEEL</STL><BRK/>
<DTE>10/07</DTE><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This guide specification covers requirements for <SCP>structural steel used 
in building construction</SCP>.  The following publications should be reviewed for 
material selection and additional specification requirements before using this 
guide specification for the following types of construction:<BRK/>
<BRK/>
Highway Bridges - American Association of State Highway and Transportation Officials (AASHTO)<BRK/>
<BRK/>
Railroad Bridges - American Railway Engineering &amp; Maintenance-of-Way Association (AREMA)<BRK/>
<BRK/>
Tower Construction - Electronic Industries Alliance (EIA), RS-222-D, "Structural 
Standards for Steel Antenna Towers and Antenna Supporting Structures."<BRK/>
<BRK/>
Edit this guide specification for project specific requirements by adding, deleting, 
or revising text.  For bracketed items, choose applicable items(s) or insert 
appropriate information.<BRK/>
<BRK/>
Remove information and requirements not required in respective project, whether 
or not brackets are present.<BRK/>
<BRK/>
Comments and suggestion on this specification are welcome and should be directed 
to the technical proponent of the specification.  A listing of <URL HREF="http://65.204.17.188/report/ufgs.html">technical proponents</URL>
, including their organization designation and telephone number, is on the Internet.<BRK/>
<BRK/>
Recommended changes to a UFGS should be submitted as a  <URL HREF="http://65.204.17.188/projnet/cms/public.html">Criteria Change Request 
(CCR)</URL>.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  The following information shall be shown on</NPR><BRK/>
<NPR>the project drawings:</NPR><BRK/>
<BRK/>
<NPR>1.  The extent and location of structural steel;</NPR><BRK/>
<BRK/>
<NPR>2.  Designations of steel members;</NPR><BRK/>
<BRK/>
<NPR>3.  Yield strength of steel used in design;</NPR><BRK/>
<BRK/>
<NPR>4.  Locations where galvanized steel will be used;</NPR><BRK/>
<BRK/>
<NPR>5.  Types of connections (welded and bolted), including adjustable runway support 
connections if overhead, top running cranes are provided;</NPR><BRK/>
<BRK/>
<NPR>6.  Locations where high-strength bolts and slip critical connections are required 
and the loads and stresses required if design is provided by Contractor; and</NPR><BRK/>
<BRK/>
<NPR>7.  The location of welds requiring nondestructive testing, along with the type 
of testing required.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<PRT><TTL>PART 1   GENERAL</TTL><BRK/>
<BRK/>
<SPT><TTL>1.1   REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This paragraph is used to list the publications cited in the text of 
the guide specification. The publications are referred to in the text by basic 
designation only and listed in this paragraph by organization, designation, 
date, and title.<BRK/>
<BRK/>
Use the Reference Wizard's Check Reference feature when you add a RID outside 
of the Section's Reference Article to automatically place the reference in the 
Reference Article.  Also use the Reference Wizard's Check Reference feature 
to update the issue dates.<BRK/>
<BRK/>
References not used in the text will automatically be deleted from this section 
of the project specification when you choose to reconcile references in the 
publish print process.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The publications listed below form a part of this specification to the extent referenced.  The publications are 
referred to within the text by the basic designation only.</TXT><BRK/>
<BRK/>
<REF><ORG>AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO)</ORG><BRK/><BRK/><RID>AASHTO HB-17</RID><RTL>(2002; Errata 2003; Errata 2005) Standard Specifications for Highway Bridges</RTL><BRK/><BRK/></REF><REF><ORG>AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)</ORG><BRK/><BRK/><RID>AISC 303</RID><RTL>(2005) Code of Standard Practice for Steel Buildings and Bridges</RTL><BRK/><BRK/><RID>AISC 317</RID><RTL>(1992; Reprint 1999) ASD Manual of Steel Construction, Vol II: Connections</RTL><BRK/><BRK/><RID>AISC 325</RID><RTL>(2005) Manual of Steel Construction</RTL><BRK/><BRK/><RID>AISC 326</RID><RTL>(2002) Detailing for Steel Construction</RTL><BRK/><BRK/><RID>AISC 341</RID><RTL>(2005; Supp 2005) Seismic Provisions for Structural Steel Buildings</RTL><BRK/><BRK/><RID>AISC 348</RID><RTL>(2000) Structural Joints Using ASTM A325 or A490 Bolts</RTL><BRK/><BRK/><RID>AISC 350</RID><RTL>(2005) Load and Resistance Factor Design (LRFD)Specification for Structural Steel Buildings</RTL><BRK/><BRK/><RID>AISC 360</RID><RTL>(2005) Specification for Structural Steel Buildings, with Commentary</RTL><BRK/><BRK/><RID>AISC 810</RID><RTL>(1997) Erection Bracing of Low-Rise Structural Steel Frames/Fisher and West</RTL><BRK/><BRK/><RID>AISC FCD</RID><RTL>(1995a)  Quality Certification Program Description</RTL><BRK/><BRK/></REF><REF><ORG>AMERICAN RAILWAY ENGINEERING AND MAINTENANCE-OF-WAY ASSOCIATION (AREMA)</ORG><BRK/><BRK/><RID>AREMA Eng Man</RID><RTL>(2008) Manual for Railway Engineering</RTL><BRK/><BRK/></REF><REF><ORG>AMERICAN WELDING SOCIETY (AWS)</ORG><BRK/><BRK/><RID>AWS A2.4</RID><RTL>(2007) Standard Symbols for Welding, Brazing and Nondestructive Examination</RTL><BRK/><BRK/><RID>AWS D1.1/D1.1M</RID><RTL>(2008) Structural Welding Code - Steel</RTL><BRK/><BRK/></REF><REF><ORG>ASME INTERNATIONAL (ASME)</ORG><BRK/><BRK/><RID>ASME B46.1</RID><RTL>(2002) Surface Texture (Surface Roughness, Waviness and Lay)</RTL><BRK/><BRK/></REF><REF><ORG>ASTM INTERNATIONAL (ASTM)</ORG><BRK/><BRK/><RID>ASTM A 108</RID><RTL>(2007) Standard Specification for Steel Bar, Carbon and Alloy, Cold-Finished</RTL><BRK/><BRK/><RID>ASTM A 123/A 123M</RID><RTL>(2008) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products</RTL><BRK/><BRK/><RID>ASTM A 143/A 143M</RID><RTL>(2007) Standard Practice for  Safeguarding Against Embrittlement of Hot-Dip Galvanized Structural Steel Products and Procedure for Detecting Embrittlement</RTL><BRK/><BRK/><RID>ASTM A 153/A 153M</RID><RTL>(2005) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware</RTL><BRK/><BRK/><RID>ASTM A 242/A 242M</RID><RTL>(2004e1) Standard Specification for High-Strength Low-Alloy Structural Steel</RTL><BRK/><BRK/><RID>ASTM A 276</RID><RTL>(2008a) Standard Specification for Stainless Steel Bars and Shapes</RTL><BRK/><BRK/><RID>ASTM A 307</RID><RTL>(2007b) Standard Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile Strength</RTL><BRK/><BRK/><RID>ASTM A 325</RID><RTL>(2007a) Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength</RTL><BRK/><BRK/><RID>ASTM A 325M</RID><RTL>(2008) Standard Specification for Structural Bolts, Steel, Heat Treated, 830 Mpa Minimum Tensile Strength (Metric)</RTL><BRK/><BRK/><RID>ASTM A 36/A 36M</RID><RTL>(2008) Standard Specification for Carbon Structural Steel</RTL><BRK/><BRK/><RID>ASTM A 490</RID><RTL>(2008a) Standard Specification for Structural Bolts, Alloy Steel, Heat Treated, 150 ksi Minimum Tensile Strength</RTL><BRK/><BRK/><RID>ASTM A 490M</RID><RTL>(2004ae1) Standard Specification for High-Strength Steel Bolts, Classes 10.9 and 10.9.3, for Structural Steel Joints (Metric)</RTL><BRK/><BRK/><RID>ASTM A 500/A 500M</RID><RTL>(2007) Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes</RTL><BRK/><BRK/><RID>ASTM A 501</RID><RTL>(2007) Standard Specification for Hot-Formed Welded and Seamless Carbon Steel Structural Tubing</RTL><BRK/><BRK/><RID>ASTM A 514/A 514M</RID><RTL>(2005) Standard Specification for High-Yield-Strength, Quenched and Tempered Alloy Steel Plate, Suitable for Welding</RTL><BRK/><BRK/><RID>ASTM A 529/A 529M</RID><RTL>(2005) Standard Specification for High-Strength Carbon-Manganese Steel of Structural Quality</RTL><BRK/><BRK/><RID>ASTM A 53/A 53M</RID><RTL>(2007) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless</RTL><BRK/><BRK/><RID>ASTM A 563</RID><RTL>(2007a) Standard Specification for Carbon and Alloy Steel Nuts</RTL><BRK/><BRK/><RID>ASTM A 563M</RID><RTL>(2007) Standard Specification for Carbon and Alloy Steel Nuts (Metric)</RTL><BRK/><BRK/><RID>ASTM A 572/A 572M</RID><RTL>(2007) Standard Specification for High-Strength Low-Alloy Columbium-Vanadium Structural Steel</RTL><BRK/><BRK/><RID>ASTM A 588/A 588M</RID><RTL>(2005) Standard Specification for High-Strength Low-Alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point, with Atmospheric Corrosion Resistance</RTL><BRK/><BRK/><RID>ASTM A 6/A 6M</RID><RTL>(2008a) Standard Specification for General Requirements for Rolled Structural Steel Bars, Plates, Shapes, and Sheet Piling</RTL><BRK/><BRK/><RID>ASTM A 618/A 618M</RID><RTL>(2004) Standard Specification for Hot-Formed Welded and Seamless High-Strength Low-Alloy Structural Tubing</RTL><BRK/><BRK/><RID>ASTM A 668/A 668M</RID><RTL>(2004) Standard Specification for Steel Forgings, Carbon and Alloy, for General Industrial Use</RTL><BRK/><BRK/><RID>ASTM A 709/A 709M</RID><RTL>(2008) Standard Specification for Structural Steel for Bridges</RTL><BRK/><BRK/><RID>ASTM A 780</RID><RTL>(2001; R 2006) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings</RTL><BRK/><BRK/><RID>ASTM A 852/A 852M</RID><RTL>(2003; R 2007) Standard Specification for Quenched and Tempered Low-Alloy Structural Steel Plate with 70 ksi (485 MPa) Minimum Yield Strength to 4 in.  (100 mm) Thick</RTL><BRK/><BRK/><RID>ASTM A 992/A 992M</RID><RTL>(2006a) Standard Specification for Structural Steel Shapes</RTL><BRK/><BRK/><RID>ASTM B 695</RID><RTL>(2004) Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel</RTL><BRK/><BRK/><RID>ASTM C 1107/C 1107M</RID><RTL>(2008) Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)</RTL><BRK/><BRK/><RID>ASTM C 827</RID><RTL>(2001a; R 2005) Change in Height at Early Ages of Cylindrical Specimens from Cementitious Mixtures</RTL><BRK/><BRK/><RID>ASTM F 436</RID><RTL>(2007a) Hardened Steel Washers</RTL><BRK/><BRK/><RID>ASTM F 436M</RID><RTL>(2004) Hardened Steel Washers (Metric)</RTL><BRK/><BRK/><RID>ASTM F 844</RID><RTL>(2007a) Washers, Steel, Plain (Flat), Unhardened for General Use</RTL><BRK/><BRK/><RID>ASTM F 959</RID><RTL>(2007a) Compressible-Washer-Type Direct Tension Indicators for Use with Structural Fasteners</RTL><BRK/><BRK/><RID>ASTM F 959M</RID><RTL>(2007) Compressible-Washer-Type Direct Tension Indicators for Use with Structural Fasteners (Metric)</RTL><BRK/><BRK/></REF><REF><ORG>CRANE MANUFACTURERS ASSOCIATION OF AMERICA (CMAA)</ORG><BRK/><BRK/><RID>CMAA 70</RID><RTL>(2004) EnviroTop Running and Bridge and Gantry Type Multiple Girder Electric Overhead Traveling Cranes, No. 70</RTL><BRK/><BRK/></REF><REF><ORG>THE SOCIETY FOR PROTECTIVE COATINGS (SSPC)</ORG><BRK/><BRK/><RID>SSPC PA 1</RID><RTL>(2000; E 2004) Shop, Field, and Maintenance Painting</RTL><BRK/><BRK/><RID>SSPC PS 13.01</RID><RTL>(1982; E 2004) Epoxy-Polyamide Painting System</RTL><BRK/><BRK/><RID>SSPC Paint 25</RID><RTL>(1997; E 2004) Paint Specification No. 25Zinc Oxide, Alkyd, Linseed Oil Primer for Use Over Hand Cleaned Steel Type I and Type II</RTL><BRK/><BRK/><RID>SSPC SP 3</RID><RTL>(2004; E 2004) Power Tool Cleaning</RTL><BRK/><BRK/><RID>SSPC SP 6</RID><RTL>(7) Commercial Blast Cleaning</RTL><BRK/><BRK/></REF></SPT><SPT><TTL>1.2   SYSTEM DESCRIPTION</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Consult with the structural designer.  Use AISC 316 and AISC 317 when 
allowable stress is used for design, and use the AISC 325 when the load and 
resistance factor is used for design.  Most designers are using AISC 316 and 
AISC 317.</NPR><AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE: The design should be checked to ensure that adequate supports at appropriate 
spacings have been provided for the installation of piping, expansion tanks, 
unit heaters, suspended ceilings and similar items. <BRK/>
<BRK/>
Provisions for using self-locking nuts should be considered where shock or vibration 
would be a problem.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide the structural steel system, including [shop primer] [galvanizing], complete and ready for use.  <TST>Structural 
steel systems including design, materials, installation, workmanship, fabrication, assembly, erection, inspection, 
quality control, and testing shall be provided in accordance with [<RID>AISC 325</RID> and <RID>AISC 317</RID>] [<RID>AISC 325</RID>] except as 
modified in this contract.</TST></TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.3   MODIFICATIONS TO REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Use the first paragraph when AISC 316 and AISC 317 (allowable stress) 
is used for design, and use the second paragraph when AISC 325 (load and resistance 
factor) is used for design.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Conform to [<RID>AISC 325</RID>], [<RID>AISC 317</RID>], [<RID>AISC 360</RID>], [<RID>AISC 303</RID>], [<RID>AISC 348</RID>], and [<RID>AISC 325</RID>], except as modified in 
this section.</TXT><BRK/>
<BRK/>
<TXT>Conform to [<RID>AISC 325</RID>], [<RID>AISC 350</RID>], [<RID>AISC 303</RID>], [<RID>AISC 348</RID>], and [<RID>AISC 325</RID>], except as modified in this section.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.4   SUBMITTALS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL 
PROCEDURES and edit the following list to reflect only the submittals required 
for the project.  Submittals should be kept to the minimum required for adequate 
quality control.<BRK/>
<BRK/>
A “G” following a submittal item indicates that the submittal requires Government 
approval.  Some submittals are already marked with a “G”.  Only delete an existing 
“G” if the submittal item is not complex and can be reviewed through the Contractor’s 
Quality Control system.  Only add a “G” if the submittal is sufficiently important 
or complex in context of the project.<BRK/>
<BRK/>
For submittals requiring Government approval on Army projects, a code of up 
to three characters within the submittal tags may be used following the "G" 
designation to indicate the approving authority.  Codes for Army projects using 
the Resident Management System (RMS) are:  "AE" for Architect-Engineer; "DO" 
for District Office (Engineering Division or other organization in the District 
Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project 
Office.  Codes following the "G" typically are not used for Navy,  Air Force, 
and NASA projects.<BRK/>
<BRK/>
Choose the first bracketed item for Navy, Air Force and NASA projects, or choose 
the second bracketed item for Army projects.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Government approval is required for submittals with a "G" designation; submittals not having a "G" designation 
are [for Contractor Quality Control approval.][for information only.  When used, a designation following the 
"G" designation identifies the office that will review the submittal for the Government.]  Submit the following 
in accordance with Section <SRF>01 33 00</SRF> SUBMITTAL PROCEDURES:</TXT><BRK/>
<BRK/>
<LST><SUB>SD-02 Shop Drawings</SUB></LST><BRK/>
<BRK/>
<ITM>[<SUB>Erection Plan</SUB>, including description of temporary supports;  <SUB>G</SUB>]</ITM><BRK/>
<BRK/>
<ITM>[<SUB>Fabrication drawings</SUB> including description of connections;  <SUB>G</SUB>]</ITM><BRK/>
<BRK/>
<LST><SUB>SD-03 Product Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Shop primer</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Welding electrodes and rods</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Load indicator washers</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Non-Shrink Grout</SUB></ITM><BRK/>
<BRK/>
<ITM>[<SUB>Load indicator bolts</SUB>]</ITM><BRK/>
<BRK/>
<ITM>Include test report for Class B primer.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-06 Test Reports</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Class B coating</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Bolts, nuts, and washers</SUB></ITM><BRK/>
<BRK/>
<ITM>Supply the certified manufacturer's mill reports which clearly show the applicable ASTM mechanical 
and chemical requirements together with the actual test results for the supplied fasteners.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-07 Certificates</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Steel</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Bolts, nuts, and washers</SUB></ITM><BRK/>
<BRK/>
<ITM>[<SUB>Galvanizing</SUB>]</ITM><BRK/>
<BRK/>
<ITM>[<SUB>Pins and rollers</SUB>]</ITM><BRK/>
<BRK/>
<ITM>[<SUB>AISC Quality Certification</SUB>]</ITM><BRK/>
<BRK/>
<ITM><SUB>Overhead, top running crane rail beam</SUB></ITM><BRK/>
<BRK/>
<ITM><SUB>Welding procedures and qualifications</SUB></ITM><BRK/>
<BRK/></SPT>
<SPT>[<TTL>1.5   <SUB>AISC QUALITY CERTIFICATION</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  AISC has a certification program in effect that confirms that a certified 
structural steel fabricating plant has the personnel, organization, experience, 
procedures, knowledge, equipment, capability, and commitment to produce fabricated 
steel of the required quality for a given category of structural steel framing.  
Consider deleting this paragraph if there is a minimal amount of steel on the 
job.  Use Category "Std" for both Complex and Conventional Steel Structures 
(replaces Sbd and Cbd categories); use Category "Sbr" for Simple Steel Bridge 
Structures; ; use Category "Cbr" for Major Steel Bridges; and use Category "MB" 
for Metal Building Systems.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Work shall be fabricated in an AISC certified Category [Sbd] [_____] fabrication plant.</TXT><BRK/>
<BRK/>
]</SPT><SPT>[<TTL>1.6   SEISMIC PROVISIONS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  When using AISC 325 (load and resistance factor) for design, and the 
project is in Seismic Zone 2 or greater, include the following paragraph.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The structural steel system shall be provided in accordance with <RID>AISC 341</RID>.</TXT><BRK/>
<BRK/>
]</SPT><SPT><TTL>1.7   QUALITY ASSURANCE</TTL><BRK/>
<BRK/>
<SPT><TTL>1.7.1   Drawing Requirements</TTL><BRK/>
<BRK/>
<TXT>Submit <SUB>fabrication drawings</SUB> for approval prior to fabrication.  Prepare in accordance with <RID>AISC 326</RID>, <RID>AISC 325</RID>
 and <RID>AISC 317</RID>.  Fabrication drawings shall not be reproductions of contract drawings.  [Sign and seal fabrication 
drawings by a professional engineer registered in the State where the project is located.]  Include complete 
information for the fabrication and erection of the structure's components, including the location, type, and 
size of bolts, welds, member sizes and lengths, connection details, blocks, copes, and cuts.  Use <RID>AWS A2.4</RID> standard 
welding symbols.  [Shoring and temporary bracing shall be designed and sealed by a registered professional engineer 
and submitted for record purposes[, with calculations,] as part of the drawings.]  Member substitutions of details 
shown on the contract drawings shall be clearly highlighted on the fabrication drawings.  Explain the reasons 
for any deviations from the contract drawings.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.7.2   Certifications</TTL><BRK/>
<BRK/>
<SPT><TTL>1.7.2.1   <SUB>Overhead, Top Running Crane Rail Beam</SUB></TTL><BRK/>
<BRK/>
<TXT>Submit written field survey results for overhead, top running crane rail beam verifying tolerance requirements, 
area out of tolerance and proposed corrective measures.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.7.2.2   <SUB>Erection Plan</SUB></TTL><BRK/>
<BRK/>
<TXT>Submit for record purposes.  Indicate the sequence of erection, temporary shoring and bracing, and a detailed 
sequence of welding, including each welding procedure required.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.7.2.3   <SUB>Welding Procedures and Qualifications</SUB></TTL><BRK/>
<BRK/>
<TXT>Prior to welding, submit certification for each welder stating the type of welding and positions qualified for, 
the code and procedure qualified under, date qualified, and the firm and individual certifying the qualification 
tests.  [If the qualification date of the welding operator is more than one-year old, the welding operator's 
qualification certificate shall be accompanied by a current certificate by the welder attesting to the fact that 
he has been engaged in welding since the date of certification, with no break in welding service greater than 
6 months.]</TXT><BRK/>
<BRK/>
<TXT>Conform to all requirements specified in <RID>AWS D1.1/D1.1M</RID>.</TXT><BRK/>
<BRK/></SPT>
</SPT></SPT></PRT><PRT><TTL>PART 2   PRODUCTS</TTL><BRK/>
<BRK/>
<SPT><TTL>2.1   <SUB>STEEL</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE: Materials appropriate to the design will be selected and remaining materials 
will be deleted.<BRK/>
<BRK/>
Designer should require materials, products, and innovative construction methods 
and techniques which are environmentally sensitive, take advantage of recycling 
and conserve natural resources. </NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Designs requiring notch strength or installation and operation at low 
temperatures will require special material selections.  Notch strength will 
be required based on design geometry or for dynamically loaded structures.  
When notch toughness is required, the supplementary requirements of the ASTM 
specification for the steel being considered should be reviewed and the appropriate 
supplementary requirements (ASTM A 6) specified.  In designs where the material 
will be exposed to temperatures below freezing, the material type should be 
checked against the proposed ambient and working temperatures for resistance 
to brittle fracture.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>2.1.1   Structural Steel</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  ASTM A 36/A 36M is a general purpose structural grade steel with a minimum 
yield strength of<MET> 250 MPa</MET><ENG> 36 ksi</ENG>.  For notch toughness, a low-alloy steel should 
be considered.  Increased corrosion resistance in non-marine environments can 
be obtained by specifying a minimum copper percentage of 0.2 percent.  Check 
availability of shapes.  Many are no longer American made.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 36/A 36M</RID>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.2   High-Strength Structural Steel</TTL><BRK/>
<BRK/>
<SPT><TTL>2.1.2.1   Low-Alloy Steel</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  ASTM A 572/A 572M steel is available in Grades<MET>345 MPa</MET><ENG> (number representing 
yield strength in ksi) 42, 50, 60, and 65, of which only Grades 42 and 50 are 
used for dynamically loaded structures</ENG>.<BRK/>
<BRK/>
ASTM A 992 covers W shapes (rolled wide flange shapes) intended for use in building 
framing.  For S, M, and HP shapes and channels, A36 or A572 Grade 50 should 
still be specified.<BRK/>
<BRK/>
ASTM A 709/A 709M covers carbon and high-strength low-alloy steel structural 
shapes, plates, and bars and quenched and tempered alloy steel for structural 
plates intended for use in bridges. Eight grades are available in four yield 
strength levels as follows:<BRK/>
<BRK/>
36 [250], 50 [345], 50S [345S], 50W [345W], HPS 50W [HPS 345W], HPS 70W [HPS 
485W], 100 [690], 100W [690W].<BRK/>
<BRK/>
Grades 50W [345W], HPS 50W [HPS 345], HPS 70W [HPS 485W], and 100W [690W] have 
enhanced atmospheric corrosion resistance.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 572/A 572M</RID> [, Grade [_____]].  [<RID>ASTM A 992/A 992M</RID> [Grade [_____]]][<RID>ASTM A 709/A 709M</RID> [Grade [_____]]].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.2.2   Quenched and Tempered Alloy Steel</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  ASTM A 514 steel has a minimum yield strength of<MET> 690 MPa up to 65 mm 
thickness and 620 MPa for 65 mm to 150 mm thickness</MET><ENG> 90 to 100 ksi, depending 
on size</ENG>, and is used for dynamically loaded structures and provides good notch 
toughness and abrasion resistance.  ASTM A 514 covers 13 grades of steel, each 
with a different chemical composition and thickness. Unless a special chemical 
composition is desired, specifying a certain grade of ASTM A 514 steel is usually 
not required.  Check availability of grades before specifying; normally only 
Grades A, F, H, and Q are stocked.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 514/A 514M</RID> [, Grade [_____]].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.2.3   Quenched and Tempered Low-Alloy Steel</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE: Check the availability of ASTM A 852.  It has been found that in some 
cases it is not available in small quantities.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 852/A 852M</RID>, 70 ksi.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.1.3   Weathering Structural Steel</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Weathering steels provide atmospheric corrosion resistance of approximately 
four times that of carbon steel without copper (normal ASTM A 36/A 36M steel) 
in non-marine environments.  ASTM A 242 steel has a minimum yield strength of<MET>
 290 to 345 MPa</MET><ENG> 42 to 50 ksi</ENG> (depending on size).  ASTM A 588 steel has a minimum 
yield strength of<MET> 290 to 345 MPa</MET> <ENG>42 to 50 ksi</ENG> (depending on size) and is available 
in four grades of steel, each with a different chemical composition.  Unless 
a special chemical composition is desired, specifying a certain grade of ASTM 
A 588 steel is not required.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 242/A 242M</RID>, Type 1; <RID>ASTM A 588/A 588M</RID>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.4   Structural Grade Carbon-Manganese Steel</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE: ASTM A 529/A 529M steel is routinely used for steel forging.  This steel 
has a minimum number of inclusions.  It has excellent welding properties, and 
may be used for the welded fabrications of special assemblies (for example, 
rocker bearings).</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 529/A 529M</RID>, high strength carbon-manganese steel of structural quality.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.5   Structural Shapes for Use in Building Framing</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE: Whenever ASTM A 992 W-Shapes are required, their location must be clearly 
identified on the contract drawings. </NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Wide flange shapes, <RID>ASTM A 992/A 992M</RID>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.6   Structural Steel Tubing</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  ASTM A 500 tubing is available in Grades A, B, C, and D with minimum 
yield strengths of<MET> 288, 290, 317, and 250 MPa</MET><ENG> 33, 42, 46, and 36 ksi</ENG> for round 
structural tubing and<MET> 269, 317, 345, and 250 MPa</MET><ENG> 39, 46, 50, and 36 ksi</ENG> for 
shaped structural tubing, respectively.  ASTM A 500 tubing may not be suitable 
for dynamically loaded structures or applications requiring notch strength.  
ASTM A 618 is available in Grades I (a or b), II, or III.  Grades I and II have 
a minimum yield strength of<MET> 315 to 345 MPa</MET><ENG> 46 to 50 ksi</ENG> (depending on size); 
Grade III has a minimum yield strength of<MET> 345 MPa</MET><ENG> 50 ksi</ENG>.  ASTM A 618, Grades 
Ia and Ib, have a corrosion resistance four times that of carbon steel in non-marine 
environments; Grade II has a corrosion resistance two times that of carbon steel 
in non-marine environments; and the corrosion resistance of Grade III can be 
increased by specifying a minimum copper percentage of 0.2 percent.  For steel 
tubing, normally only ASTM A 500, Grade B is stocked.  ASTM A 618 tubing is 
available<MET> ASTM A 325M</MET><ENG> ASTM A 325</ENG> and<MET> ASTM A 490M</MET><ENG> ASTM A 490</ENG> only in round shapes.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 500/A 500M</RID>, Grade [B] [_____]; <RID>ASTM A 501</RID>; [<RID>ASTM A 618/A 618M</RID>, Grade [_____]].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.7   Steel Pipe</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  ASTM A 53/A 53M pipe, Type E (Electric-resistance Welded) and Type S 
(Seamless), Grade B, has a minimum yield strength of<MET> 245 MPa</MET><ENG> 35 ksi</ENG> and is available 
in the following weight classes:  STD (Standard), XS (Extra Strong), and XXS 
(Double-extra Strong).</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 53/A 53M</RID>, Type E or S, Grade B, weight class [STD (Standard)] [_____].</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2   <SUB>BOLTS, NUTS, AND WASHERS</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Commonly used bolts, nuts, and washers are listed under the applicable 
type of steel using the same terminology specified in "Steel" paragraph. Verify 
material selection with the designer and modify if required.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Designs requiring notch strength or installation and operation at low 
temperatures will require special material selections.  Notch strength will 
be required based on design geometry or for dynamically loaded structures.  
When notch toughness is required, the supplementary requirements of the ASTM 
specification for the steel being considered should be reviewed and the appropriate 
supplementary requirements (ASTM A 6) specified.  In designs where the material 
will be exposed to temperatures below freezing, the material type should be 
checked against the proposed ambient and working temperatures for resistance 
to brittle fracture.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide the following unless indicated otherwise.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.1   Structural Steel [, Steel Pipe]</TTL><BRK/>
<BRK/>
<SPT><TTL>2.2.1.1   Bolts</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Do not galvanize ASTM A 490 bolts.  When galvanizing ASTM A 325 bolts 
limit hardness of bolts to Rockwell C-32.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Do not mix bolt material specifications<MET> ASTM A 325M and ASTM A 490M</MET><ENG> ASTM 
A 325 and ASTM A 490</ENG> on the same diameter bolts in high strength connections.  
Do not place <MET> ASTM A 325M and ASTM A 490M</MET><ENG> ASTM A 325 and ASTM A 490</ENG> bolts, which 
have a hardness equal to or in excess of Rockwell C-32, in contact with a galvanized 
surface. The<MET> ASTM A 325M and ASTM A 490M</MET><ENG> ASTM A 325 and ASTM A 490</ENG> bolts specified 
are for a maximum diameter of<MET> M36</MET><ENG> 1.5 inch</ENG>. If larger bolts are required, include 
the following ASTM publications in reference article:</NPR><BRK/>
<BRK/>
<NPR>ASTM A 354 - Quenched and Tempered Alloy Steel Bolts, Studs, and Other Externally 
Threaded Fasteners</NPR><BRK/>
<BRK/>
<NPR>ASTM A 449 - Quenched and Tempered Steel Bolts and Studs.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 307</RID>, Grade A; [<MET><RID>ASTM A 325M</RID></MET> <ENG><RID>ASTM A 325</RID></ENG>, Type 1], [<MET><RID>ASTM A 490M</RID></MET> <ENG><RID>ASTM A 490</RID></ENG>, Type 1].  The bolt heads and 
the nuts of the supplied fasteners must be marked with the manufacturer's identification mark, the strength grade 
and type specified by ASTM specifications.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.1.2   Nuts</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM A 563M</RID>, Grade A, heavy hex style, except nuts under M36 may be provided in hex style.  </MET><ENG><RID>ASTM A 563</RID>, Grade 
and Style for applicable ASTM bolt standard recommended.</ENG></TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.1.3   Washers</TTL><BRK/>
<BRK/>
<TXT><RID>ASTM F 844</RID> washers for <RID>ASTM A 307</RID> bolts, and<MET> <RID>ASTM F 436M</RID></MET><ENG> <RID>ASTM F 436</RID></ENG> washers for<MET> <RID>ASTM A 325M</RID></MET><ENG> <RID>ASTM A 325</RID></ENG> and<MET> <RID>ASTM A 490M</RID></MET><ENG>
 <RID>ASTM A 490</RID></ENG> bolts.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.2   High-Strength Structural Steel [and Structural Steel Tubing]</TTL><BRK/>
<BRK/>
<SPT><TTL>2.2.2.1   Bolts</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Do not galvanize ASTM A 490 bolts.  When galvanizing ASTM A 325 bolts 
limit hardness of bolts to Rockwell C-32.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Do not mix bolt material specifications<MET> ASTM A 325M and ASTM A 490M</MET><ENG> ASTM 
A 325 and ASTM A 490</ENG> on the same diameter bolts in high strength connections.  
Do not place<MET> ASTM A 325M and ASTM A 490M</MET><ENG> ASTM A 325 and ASTM A 490</ENG> bolts, which 
have a hardness equal or in excess of Rockwell C-32, in contact with a galvanized 
surface.  The<MET> ASTM A 325M and ASTM A 490M</MET><ENG> ASTM A 325 and ASTM A 490</ENG> bolts specified 
are for a maximum diameter of<MET> M36</MET><ENG> 1.5 inch</ENG>. If larger bolts are required, include 
the following ASTM publications in reference article:</NPR><BRK/>
<BRK/>
<NPR>ASTM A 354 - Quenched and Tempered Alloy Steel Bolts, Studs, and Other Externally 
Threaded Fasteners</NPR><BRK/>
<BRK/>
<NPR>ASTM A 449 - Quenched and Tempered Steel Bolts and Studs.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><MET><RID>ASTM A 325M</RID></MET> <ENG><RID>ASTM A 325</RID></ENG>, Type 1<MET> <RID>ASTM A 490M</RID></MET> <ENG> <RID>ASTM A 490</RID></ENG>, Type 1 or 2.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.2.2   Nuts</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM A 563M</RID></MET> <ENG><RID>ASTM A 563</RID></ENG>, Grade and Style as specified in the applicable ASTM bolt standard.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.2.3   Washers</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM F 436M</RID></MET> <ENG><RID>ASTM F 436</RID></ENG>, plain carbon steel.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.3   Weathering Structural Steel</TTL><BRK/>
<BRK/>
<SPT><TTL>2.2.3.1   Bolts</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM A 325M</RID></MET> <ENG><RID>ASTM A 325</RID></ENG>, Type 3;<MET> <RID>ASTM A 490M</RID></MET> <ENG> <RID>ASTM A 490</RID></ENG>, Type 3.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.3.2   Nuts</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM A 563M</RID></MET> <ENG><RID>ASTM A 563</RID></ENG>, heavy hex style, Grade DH3, except Grade C3 may be furnished for<MET> <RID>ASTM A 325M</RID></MET><ENG> <RID>ASTM A 325</RID></ENG>
 bolts.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.3.3   Washers</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM F 436M</RID></MET> <ENG><RID>ASTM F 436</RID></ENG>, weathering steel.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.4   Foundation Anchorage</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  For most jobs, ASTM A 307 anchor bolts are used.  If high tensile loads 
are anticipated, the designer should consider the use of ASTM A 449 anchor bolts.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>2.2.4.1   Anchor Bolts</TTL><BRK/>
<BRK/>
<TXT><RID>ASTM A 307</RID>.  [Stainless steel [Type 304][Type 316] conforming to <RID>ASTM A 276</RID>.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.4.2   Anchor Nuts</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM A 563</RID></MET><ENG> <RID>ASTM A 563</RID></ENG>, Grade A, hex style.  [Stainless steel [Type 304][Type 316] conforming to <RID>ASTM A 276</RID>.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.4.3   Anchor Washers</TTL><BRK/>
<BRK/>
<TXT><RID>ASTM F 844</RID>.  [Stainless steel [Type 304][Type 316] conforming to <RID>ASTM A 276</RID>.]</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.5   <SUB>Load Indicator Washers</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Include bracketed phrase if load indicator washers are to be galvanized.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><MET><RID>ASTM F 959M</RID></MET> <ENG><RID>ASTM F 959</RID></ENG>.  [Provide <RID>ASTM B 695</RID>, Class 50, Type 1 galvanizing.]</TXT><BRK/>
<BRK/></SPT>
<SPT>[<TTL>2.2.6   <SUB>Load Indicator Bolts</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Drawings or specifications should identify where these items are used.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><MET><RID>ASTM A 325M</RID></MET> <ENG><RID>ASTM A 325</RID></ENG>, Type 1;<MET> <RID>ASTM A 490M</RID></MET><ENG> <RID>ASTM A 490</RID></ENG>, Type 1, with a manufactured notch between the bolt tip 
and threads.  The bolt shall be designed to react to the opposing rotational torques applied by the installation 
wrench, with the bolt tip automatically shearing off when the proper tension is obtained.</TXT><BRK/>
<BRK/>
]</SPT><SPT>[<TTL>2.2.7   Self-Locking Nuts</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Drawings or specifications should identify where these items are used.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide nuts with a locking pin set in the nut.  The locking pin shall slide along the bolt threads, and by reversing 
the direction of the locking pin, the nut shall be removed without damaging the nut or bolt.  Provide stainless 
steel locking pins.</TXT><BRK/>
<BRK/>
]</SPT></SPT><SPT><TTL>2.3   STRUCTURAL STEEL ACCESSORIES</TTL><BRK/>
<BRK/>
<SPT><TTL>2.3.1   <SUB>Welding Electrodes and Rods</SUB></TTL><BRK/>
<BRK/>
<TXT><RID>AWS D1.1/D1.1M</RID>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.2   <SUB>Non-Shrink Grout</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Some nonshrink grouts derive their nonshrink properties from an increase 
in volume of metal due to oxidation.  Where oxidation is not desired for appearance 
sake, specify nonmetallic grout.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM C 1107/C 1107M</RID>, with no <RID>ASTM C 827</RID> shrinkage.  [Grout shall be nonmetallic.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.3   Welded Shear Stud Connectors</TTL><BRK/>
<BRK/>
<TXT><RID>AWS D1.1/D1.1M</RID>.</TXT><BRK/>
<BRK/></SPT>
<SPT>[<TTL>2.3.4   <SUB>Pins and Rollers</SUB></TTL><BRK/>
<BRK/>
<TXT><RID>ASTM A 668/A 668M</RID>, Class C, D, F, or G; <RID>ASTM A 108</RID>, Grades 1016 to 1030.  Provide as specified in <RID>AASHTO HB-17</RID>
, Division II, Sections 10.26 and 10.27, except provide pins in lengths to extend a minimum of<MET> 6 mm</MET><ENG> 0.25 inch</ENG>
 beyond the outside faces of the connected parts.</TXT><BRK/>
<BRK/>
]</SPT></SPT><SPT><TTL>2.4   <SUB>SHOP PRIMER</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Shop primer specified is for structural steel located inside a typical 
building.  For buildings that will have a lot of structural steel exposed to 
view inside a building (i.e. hangars, maintenance shops), exterior structural 
steel, or other locations that will require a better shop primer, use of a zinc 
rich primer and epoxy coating system is recommended.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>SSPC Paint 25</RID>, (alkyd primer) or  <RID>SSPC PS 13.01</RID> epoxy-polyamide, green primer (Form 150) type 1, except provide 
a <SUB>Class B coating</SUB> in accordance with <RID>AISC 325</RID> and <RID>AISC 317</RID> for slip critical joints.  Primer shall conform to 
Federal, State, and local VOC regulations.  If flash rusting occurs, re-clean the surface prior to application 
of primer.</TXT><BRK/>
<BRK/></SPT>
<SPT>[<TTL>2.5   <SUB>GALVANIZING</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Most structural steel is painted.  If galvanized items are required, 
they must be indicated or specified.  The galvanizing specified is by the hot-dip 
process.  This process requires large amounts of energy and unevenly heats steel 
sections that are either large or thick, occasionally warping the steel sections.  
Using zinc coating by thermal spraying (metallizing) as an alternative to hot-dip 
galvanizing should be considered for certain steel sections.  The following 
American Welding Society (AWS) publications should be consulted for further 
information:</NPR><BRK/>
<BRK/>
<NPR>TS-85 - Thermal Spraying - Practice, Theories, and Application</NPR><BRK/>
<BRK/>
<NPR>C2.2-67 - Recommended Practices for Metallizing with Aluminum and Zinc for Protection 
of Iron and Steel.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASTM A 123/A 123M</RID> or <RID>ASTM A 153/A 153M</RID>, as applicable, unless specified otherwise galvanize after fabrication 
where practicable.</TXT><BRK/>
<BRK/>
]</SPT><SPT>[<TTL>2.6   OVERHEAD, TOP RUNNING CRANE RAIL</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Crane rail shape and size shall be based on the crane capacity and maximum 
wheel loads.  Consult the crane manufacturer for their recommended rail.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>[<RID>AISC 325</RID> and <RID>AISC 317</RID>] [<RID>AISC 325</RID>] [<RID>AREMA Eng Man</RID>], [_____]<MET> kg</MET><ENG> pound</ENG> crane rail section and [bolted] [welded] 
joints.  Provide rail fasteners and a minimum rail length of<MET> 3000 mm</MET><ENG> 10 feet</ENG>.</TXT><BRK/>
<BRK/>
]</SPT><SPT><TTL>2.7   FABRICATION</TTL><BRK/>
<BRK/>
<SPT><TTL>2.7.1   Markings</TTL><BRK/>
<BRK/>
<TXT>Prior to erection, members shall be identified by a painted erection mark. Connecting parts assembled in the 
shop for reaming holes in field connections shall be match marked with scratch and notch marks.  Do not locate 
erection markings on areas to be welded [or on surfaces of weathering steels that will be exposed in the completed 
structure].  Do not locate match markings in areas that will decrease member strength or cause stress concentrations.  
[Affix embossed tags to hot-dipped galvanized members.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.7.2   Shop Primer</TTL><BRK/>
<BRK/>
<TXT>Shop prime structural steel, except as modified herein, in accordance with <RID>SSPC PA 1</RID>.  Do not prime steel surfaces 
embedded in concrete, galvanized surfaces, [surfaces to receive sprayed-on fireproofing,] [surfaces to receive 
epoxy coatings,] [surfaces designed as part of a composite steel concrete section,] or surfaces within<MET> 13 mm</MET><ENG> 
0.5 inch</ENG> of the toe of the welds prior to welding (except surfaces on which metal decking is to be welded).  
Slip critical surfaces shall be primed with a Class B coating.  Prior to assembly, prime surfaces which will 
be concealed or inaccessible after assembly.  Do not apply primer in foggy or rainy weather; when the ambient 
temperature is below<MET> 7 degrees C or over 35 degrees C</MET><ENG> 45 degrees F or over 95 degrees F</ENG>; or when the primer may 
be exposed to temperatures below<MET> 4 degrees C</MET><ENG> 40 degrees F</ENG> within 48 hours after application, unless approved 
otherwise by the Contracting Officer.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.7.2.1   Cleaning</TTL><BRK/>
<BRK/>
<TXT><RID>SSPC SP 6</RID>, except steel exposed in spaces above ceilings, attic spaces, furred spaces, and chases that will be 
hidden to view in finished construction may be cleaned to <RID>SSPC SP 3</RID> when recommended by the shop primer manufacturer.  
Maintain steel surfaces free from rust, dirt, oil, grease, and other contaminants through final assembly.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.7.2.2   Primer</TTL><BRK/>
<BRK/>
<TXT>Apply primer to a minimum dry film thickness of<MET> 0.05 mm</MET><ENG> 2.0 mil</ENG> except provide the Class B coating for slip critical 
joints in accordance with the coating manufacturer's recommendations.  Repair damaged primed surfaces with an 
additional coat of primer.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT>[<TTL>2.7.3   [Fireproofing] [and] [Epoxy] Coated Surfaces</TTL><BRK/>
<BRK/>
<TXT>Surfaces to receive [sprayed-on fireproofing] [epoxy] coatings shall be cleaned and prepared in accordance with 
the manufacturer's recommendations, and as specified in Section <SRF>07 81 00</SRF> SPRAY-APPLIED FIREPROOFING.</TXT><BRK/>
<BRK/>
]</SPT><SPT>[<TTL>2.7.4   Surface Finishes</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  AISC states "finished" surfaces, where identified, should have a maximum 
roughness of 500. For pins and bearing surfaces, a maximum roughness of 125, 
in lieu of 500, is recommended.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>ASME B46.1</RID> maximum surface roughness of 125 for pin, pinholes, and sliding bearings, unless indicated otherwise.</TXT><BRK/>
<BRK/>
]</SPT></SPT><SPT><TTL>2.8   DRAINAGE HOLES</TTL><BRK/>
<BRK/>
<TXT>Adequate drainage holes shall be drilled to eliminate water traps.  Hole diameter shall be<MET> 13 mm</MET><ENG> 1/2 inch</ENG> and 
location shall be indicated on the detail drawings.  Hole size and location shall not affect the structural integrity.</TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 3   EXECUTION</TTL><BRK/>
<BRK/>
<SPT><TTL>3.1   FABRICATION</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE: If bearing-type high strength bolted connections are required, delete 
the painting exception for contact surfaces of friction-type high-strength bolted connections.<BRK/>
<BRK/>
AISC fabrication plant certification is required for the structural steel to 
be furnished for the project.  The requirement for AISC fabrication plant certification 
may be deleted at the discretion of the designer.  This decision will be based 
on the complexity of the design and the criticality of the connections.  If 
moment connections are involved, AISC certification is recommended.  The quantity 
of structural steel in the project should be a point of consideration.  The 
certification categories, as defined in AISC FCD, are:<BRK/>
<BRK/>
a.  Conventional Steel Building Structures<BRK/>
<BRK/>
b.  Simple Steel Bridge Structures<BRK/>
<BRK/>
c.  Complex Steel Building Structures<BRK/>
<BRK/>
d.  Major Steel Bridges<BRK/>
<BRK/>
e.  Metal Building Systems<BRK/>
<BRK/>
f.  Supplement:  Auxiliary and Support Structures for Nuclear Power Plants - 
This supplement, applicable to nuclear plant structures designed under the AISC 
Specification, but not to pressure-retaining structures, offers utility companies 
and designers of nuclear power plants a certification program that will eliminate 
the need for many of the more costly, conflicting programs now in use.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Fabrication shall be in accordance with the applicable provisions of <RID>AISC 325</RID>.  Fabrication and assembly shall 
be done in the shop to the greatest extent possible.  The fabricating plant shall be certified under the <RID>AISC FCD</RID>
 for Category [_____] [Supplement] structural steelwork.<BRK/>
<BRK/>
Compression joints depending on contact bearing shall have a surface roughness not in excess of <MET>13 micrometer</MET>
 <ENG>500 micro inch</ENG> as determined by <RID>ASME B46.1</RID>, and ends shall be square within the tolerances for milled ends specified 
in <RID>ASTM A 6/A 6M</RID>.<BRK/>
<BRK/>
Structural steelwork, except surfaces of steel to be encased in concrete, surfaces to be field welded, surfaces 
to be fireproofed, and contact surfaces of friction-type high-strength bolted connections shall be prepared for 
painting in accordance with [endorsement "P" of <RID>AISC FCD</RID>] [_____] and primed with the specified paint.</TXT><BRK/>
<BRK/>
<TXT>Shop splices of members between field splices will be permitted only where indicated on the Contract Drawings.  
Splices not indicated require the approval of the Contracting Officer.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.2   INSTALLATION</TTL><BRK/>
<BRK/>
<SPT>[<TTL>3.2.1   Overhead, Top Running Cranes</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Consult with the structural designer.  Use AISC 316 and AISC 317 when 
allowable stress is used for design, and use the AISC 325 when the load and 
resistance factor is used for design.  Most designers are using AISC 316 and 
AISC 317.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Do not splice truss top and bottom chords except as approved by the Contracting Officer.  Chord splices shall 
occur at panel joints at approximately the third point of the span.  The center of gravity lines of truss members 
shall intersect at panel points unless otherwise approved by the Contracting Officer.  When the center of gravity 
lines do not intersect at a panel point, provisions shall be made for the stresses due to eccentricity.  Cumber 
of trusses shall be<MET> 3 mm</MET><ENG> 1/8 inch</ENG> in 10 feet unless otherwise indicated.</TXT><BRK/>
<BRK/>
<TXT>Runway rails and beams shall be provided in accordance with [<RID>AISC 325</RID> and <RID>AISC 317</RID>] [<RID>AISC 325</RID>] and <RID>CMAA 70</RID>, except 
that in case of conflict, the requirements of <RID>CMAA 70</RID> shall govern.  In addition, provide a maximum vertical 
difference of<MET> 0.8 mm</MET><ENG> 0.03 inch</ENG> in the elevation between adjacent runway rail tops and adjacent runway beam tops 
at joints.  Provide adjustable runway support connections to allow placement of the crane rails and beams to 
the tolerances specified.  Stagger runway rail joints a minimum of one foot, except that the stagger shall not 
be the same as the crane wheel spacing.</TXT><BRK/>
<BRK/>
]</SPT></SPT><SPT><TTL>3.3   ERECTION</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE: For low-rise structural steel buildings, the designer must design the 
structure to be erected in accordance with AISC 810. </NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<ITM INDENT="-0.33">a.  Erection of structural steel, except as indicated in item b. below, shall be in accordance 
with the applicable provisions of [<RID>AISC 325</RID>] [<RID>AISC 325</RID>] [endorsement F of <RID>AISC FCD</RID>].  Erection 
plan shall be reviewed, stamped and sealed by a licensed structural engineer.</ITM><BRK/>
<BRK/>
<ITM INDENT="-0.33">b.  For low-rise structural steel buildings (<MET>18 m</MET> <ENG>60 feet</ENG> tall or less and a maximum of 2 stories), 
the erection plan shall conform to <RID>AISC 303</RID> and the structure shall be erected in accordance 
with<RID>AISC 810</RID>.</ITM><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Good design practice provides most connections and members with proper 
drainage.  If ponding of water cannot be avoided, specify a waterproofing material 
to suit the job's specific needs.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide for drainage in structural steel.  After final positioning of steel members, provide full bearing under 
base plates and bearing plates using nonshrink grout.  Place nonshrink grout in accordance with the manufacturer's 
instructions.</TXT><BRK/>
<BRK/>
<SPT><TTL>3.3.1   STORAGE</TTL><BRK/>
<BRK/>
<TXT>Material shall be stored out of contact with the ground in such manner and location as will minimize deterioration.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>3.4   CONNECTIONS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Use AISC 360 for designs using AISC 316 and AISC 317 (allowable stress), 
and use AISC 350 for designs using AISC 325 (load and resistance factor).</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Except as modified in this section, connections not detailed shall be designed in accordance with [<RID>AISC 360</RID>] 
[<RID>AISC 350</RID>].  Build connections into existing work.  Do not tighten anchor bolts set in concrete with impact torque 
wrenches.  Punch, subpunch and ream, or drill bolt [and pin] holes perpendicular to the surface of the member.  
Holes shall not be cut or enlarged by burning.  Bolts, nuts, and washers shall be clean of dirt and rust, and 
lubricated immediately prior to installation.</TXT><BRK/>
<BRK/>
<SPT><TTL>3.4.1   Common Grade Bolts</TTL><BRK/>
<BRK/>
<TXT><RID>ASTM A 307</RID> bolts shall be tightened to a "snug tight" fit.  "Snug tight" is the tightness that exists when plies 
in a joint are in firm contact.  If firm contact of joint plies cannot be obtained with a few impacts of an impact 
wrench, or the full effort of a man using a spud wrench, contact the Contracting Officer for further instructions.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.4.2   High-Strength Bolts</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  The four bolt tightening methods currently allowed by AISC will provide 
acceptable results if bolt assemblies are kept free of dirt and rust, if properly 
lubricated, and if proper installation procedures are followed.  Because these 
conditions are rarely encountered during normal construction, use only direct 
tension indicator tightening methods where slip critical connections are required.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Include bracketed item for all jobs and delete the first sentence of 
the paragraph.  Slip critical connections must be identified on the drawings.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><MET><RID>ASTM A 325M</RID></MET> <ENG><RID>ASTM A 325</RID></ENG> and<MET> <RID>ASTM A 490M</RID></MET> <ENG> <RID>ASTM A 490</RID></ENG> bolts shall be fully tensioned to 70 percent of their minimum 
tensile strength.  [Provide load indicator bolts or washers in all [<MET><RID>ASTM A 325M</RID></MET> <ENG><RID>ASTM A 325M</RID></ENG>] [or] [<MET><RID>ASTM A 490M</RID></MET>
 <ENG><RID>ASTM A 490</RID></ENG>] bolted connections, except provide only load indicator washers for slip critical connections.  Direct 
tension indicator tightening, [, or installation of alternate design fasteners,] shall be the only acceptable 
tightening methods.  Use only direct tension indicator tightening for slip critical connections.]  Bolts shall 
be installed in connection holes and initially brought to a snug tight fit.  After the initial tightening procedure, 
bolts shall then be fully tensioned, progressing from the most rigid part of a connection to the free edges.</TXT><BRK/>
<BRK/>
<SPT><TTL>3.4.2.1   Installation of Load Indicator Washers (LIW)</TTL><BRK/>
<BRK/>
<TXT><MET><RID>ASTM F 959M</RID></MET> <ENG><RID>ASTM F 959</RID></ENG>.  Where possible, the LIW shall be installed under the bolt head and the nut shall be 
tightened.  If the LIW is installed adjacent to the turned element, provide a flat<MET> <RID>ASTM F 436M</RID></MET><ENG> <RID>ASTM F 436</RID></ENG> washer 
between the LIW and nut when the nut is turned for tightening, and between the LIW and bolt head when the bolt 
head is turned for tightening.  In addition to the LIW, provide flat<MET> <RID>ASTM F 436M</RID></MET><ENG> <RID>ASTM F 436</RID></ENG> washers under both 
the bolt head and nut when<MET> <RID>ASTM A 490M</RID></MET><ENG> <RID>ASTM A 490</RID></ENG> bolts are used.</TXT><BRK/>
<BRK/></SPT>
</SPT></SPT><SPT><TTL>3.5   GAS CUTTING</TTL><BRK/>
<BRK/>
<TXT>Use of gas-cutting torch in the field for correcting fabrication errors will not be permitted on any major member 
in the structural framing.  Use of a gas cutting torch will be permitted on minor members not under stress only 
after approval has been obtained from the Contracting Officers.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.6   WELDING</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  For jobs in Iceland, in lieu of AWS welders and inspectors, use "Technological 
Institute of Iceland" certified welders and inspectors.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Section 05090 WELDING, STRUCTURAL must be used for all buildings in Seismic 
Design Categories D, E and F and buildings in category C when designed in accordance 
with the 1997 AISC Seismic Provisions for Structural Steel Buildings.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>AWS D1.1/D1.1M</RID>[, except use only shielded metal arc welding and low hydrogen electrodes for <RID>ASTM A 514/A 514M</RID>
 steel.  Do not stress relieve <RID>ASTM A 514/A 514M</RID> steel by heat treatment].  [Grind exposed welds smooth as indicated.]  
Provide <RID>AWS D1.1/D1.1M</RID> qualified welders, welding operators, and tackers.</TXT><BRK/>
<BRK/>
<TXT>The Contractor shall develop and submit the Welding Procedure Specifications (WPS) for all welding, including 
welding done using prequalified procedures.  Prequalified procedures may be submitted for information only; however, 
procedures that are not prequalified shall be submitted for approval.</TXT><BRK/>
<BRK/>
<SPT><TTL>3.6.1   Removal of Temporary Welds, Run-Off Plates, and Backing Strips</TTL><BRK/>
<BRK/>
<TXT>[Removal is not required] [Remove only from finished areas].</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>3.7   SHOP PRIMER REPAIR</TTL><BRK/>
<BRK/>
<TXT>Repair shop primer in accordance with the paint manufacturer's recommendation for surfaces damaged by handling, 
transporting, cutting, welding, or bolting.</TXT><BRK/>
<BRK/>
<SPT><TTL>3.7.1   Field Priming</TTL><BRK/>
<BRK/>
<TXT>Field priming of steel exposed to the weather, or located in building areas without HVAC for control of relative 
humidity.  After erection, the field bolt heads and nuts, field welds, and any abrasions in the shop coat shall 
be cleaned and primed with paint of the same quality as that used for the shop coat.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT>[<TTL>3.8   GALVANIZING REPAIR</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Most structural steel is painted.  If galvanized items are required, 
they must be indicated or specified.  The galvanizing specified is by the hot-dip 
process.  This process requires large amounts of energy and unevenly heats steel 
sections that are either large or thick, occasionally warping the steel sections.  
Using zinc coating by thermal spraying (metallizing) as an alternative to hot-dip 
galvanizing should be considered for certain steel sections.  The following 
American Welding Society (AWS) publications should be consulted for further 
information:</NPR><BRK/>
<BRK/>
<NPR>TS-85 - Thermal Spraying - Practice, Theories, and Application</NPR><BRK/>
<BRK/>
<NPR>C2.2-67 - Recommended Practices for Metallizing with Aluminum and Zinc for Protection 
of Iron and Steel.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide as indicated or specified.  Galvanize after fabrication where practicable.  Repair damage to galvanized 
coatings using <RID>ASTM A 780</RID> zinc rich paint for galvanizing damaged by handling, transporting, cutting, welding, 
or bolting.  Do not heat surfaces to which repair paint has been applied.</TXT><BRK/>
<BRK/>
]</SPT><SPT><TTL>3.9   FIELD QUALITY CONTROL</TTL><BRK/>
<BRK/>
<TXT><TST>Perform field tests, and provide labor, equipment, and incidentals required for testing[, except that electric 
power for field tests will be furnished as set forth in Division 1].  The Contracting Officer shall be notified 
in writing of defective welds, bolts, nuts, and washers within 7 working days of the date of weld inspection.</TST></TXT><BRK/>
<BRK/>
<SPT><TTL>3.9.1   Welds</TTL><BRK/>
<BRK/>
<SPT><TTL>3.9.1.1   Visual Inspection</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  For jobs in Iceland, in lieu of AWS welders and inspectors, use "Technological 
Institute of Iceland" certified welders and inspectors.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>AWS D1.1/D1.1M</RID>.  Furnish the services of AWS-certified welding inspectors for fabrication and erection inspection 
and testing and verification inspections.  <TST>Welding inspectors shall visually inspect and mark welds, including 
fillet weld end returns.</TST></TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.9.1.2   Nondestructive Testing</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  The designer shall indicate the location of test welds and types of testing 
desired.  The following information is presented as guidance.  Dye penetrant 
testing detects small surface defects by enhancing the visibility of the flaw.  
Magnetic particle testing detects surface cracks and near-surface cracks; this 
test provides more information than the dye penetrant testing, and for approximately 
the same cost.  Ultrasonic and radiographic testing detect surface and internal 
cracks, delaminations, lack of fusion, and density and thickness variations; 
these tests offer basically the same information, but their usage is limited 
by location and type of weld.  Generally, fillet welds can only be dye penetrant 
or magnetic particle tested.  Complete penetration welds at butt joints should 
be radiographically tested; all other complete penetration welds should be ultrasonically 
tested.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>AWS D1.1/D1.1M</RID>.  Test locations shall be [as indicated] [selected by the Contracting Officer].  <TST>If more than 
[20] [_____] percent of welds made by a welder contain defects identified by testing, then all welds made by 
that welder shall be tested by radiographic or ultrasonic testing</TST>, as approved by the Contracting Officer.  When 
all welds made by an individual welder are required to be tested, magnetic particle testing shall be used only 
in areas inaccessible to either radiographic or ultrasonic testing.  Retest defective areas after repair.</TXT><BRK/>
<BRK/>
<ITM INDENT="-0.33">a.  Testing frequency:  Provide the following types and number of tests:</ITM><BRK/>
<TBL><THD><BRK/>
          <HL1>Test Type</HL1>                     <HL1>Number of Tests</HL1><BRK/></THD>
<BRK/>
          Radiographic                      [_____]<BRK/>
<BRK/>
          Ultrasonic                        [_____]<BRK/>
<BRK/>
          Magnetic Particle                 [_____]<BRK/>
<BRK/>
          Dye Penetrant                     [_____]<BRK/></TBL>
<BRK/></SPT>
</SPT><SPT><TTL>3.9.2   Load Indicator Washers</TTL><BRK/>
<BRK/>
<SPT><TTL>3.9.2.1   Load Indicator Washer Compression</TTL><BRK/>
<BRK/>
<TXT><TST>Load indicator washers shall be tested</TST> in place to verify that they have been compressed sufficiently to provide 
the<MET> 0.38 mm</MET><ENG> 0.015 inch</ENG> gap when the load indicator washer is placed under the bolt head and the nut is tightened, 
and to provide the<MET> 0.13 mm</MET><ENG> 0.005 inch</ENG> gap when the load indicator washer is placed under the turned element, 
as required by<MET> <RID>ASTM F 959M</RID></MET><ENG> <RID>ASTM F 959</RID></ENG>.</TXT><BRK/>
<BRK/></SPT>
<SPT>[<TTL>3.9.2.2   Load Indicator Gaps</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Use this paragraph on large complex structural steel systems or on jobs 
where minimal on site inspection is expected.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>In addition to the above testing, an independent testing agency as approved by the Contracting Officer, shall <TST>
test in place the load indicator gaps</TST>on 20 percent of the installed load indicator washers to verify that the<MET>
 <RID>ASTM F 959M</RID></MET><ENG> <RID>ASTM F 959</RID></ENG> load indicator gaps have been achieved.  If more than 10 percent of the load indicators 
tested have not been compressed sufficiently to provide the average gaps required by<MET> <RID>ASTM F 959M</RID></MET><ENG> <RID>ASTM F 959</RID></ENG>, 
then all in place load indicator washers shall be tested to verify that the<MET> <RID>ASTM F 959M</RID></MET> <ENG><RID>ASTM F 959</RID></ENG> load indicator 
gaps have been achieved.  Test locations shall be selected by the Contracting Officer.</TXT><BRK/>
<BRK/>
]</SPT></SPT><SPT>[<TTL>3.9.3   Overhead, Top Running Crane Rails and Beams</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Include paragraph for overhead, top running cranes.  Underhung bridge 
cranes and monorail systems are normally provided with their own patented track 
systems and do not normally require the tight tolerances specified for overhead, 
top running cranes.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><TST>Runway rails and beams shall be surveyed (horizontally and vertically) after installation to verify compliance 
with the tolerance requirements of <RID>CMAA 70</RID> and the additional tolerance requirements specified in this section.  
After each survey, submit a written report to the Contracting Officer with the following information:  field 
survey results, tolerance requirements, areas out of tolerance, and proposed corrective measures. Proposed corrective 
measures shall be approved by the Contracting Officer. Following completion of corrective measures, areas that 
were previously out of tolerance shall be re-surveyed and another written report shall be furnished to the Contracting 
Officer.  Field surveys shall be performed and sealed by a registered land surveyor.</TST></TXT><BRK/>
<BRK/>
]</SPT><SPT><TTL>3.9.4   High-Strength Bolts</TTL><BRK/>
<BRK/>
<SPT><TTL>3.9.4.1   Testing Bolt, Nut, and Washer Assemblies</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Use AISC 348 for designs using AISC 316 and AISC 317 (allowable stress), 
and use AISC 348 for designs using AISC 325 (load and resistance factor).</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><TST>Test a minimum of [3] [_____] bolt, nut, and washer assemblies</TST> from each mill certificate batch in a tension 
measuring device at the job site prior to the beginning of bolting start-up.  Demonstrate that the bolts and 
nuts, when used together, can develop tension not less than the provisions specified in [<RID>AISC 348</RID>] [<RID>AISC 348</RID>], 
Table 4, depending on bolt size and grade.  The bolt tension shall be developed by tightening the nut.  A representative 
of the manufacturer or supplier shall be present to ensure that the fasteners are properly used, and to demonstrate 
that the fastener assemblies supplied satisfy the specified requirements.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.9.4.2   Inspection</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Use AISC 348 for designs using AISC 316 and AISC 317 (allowable stress), 
and use AISC 348 for designs using AISC 325 (load and resistance factor).</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Inspection procedures shall be in accordance with [<RID>AISC 348</RID>] [<RID>AISC 348</RID>], Section 9.  Confirm and report to the 
Contracting Officer that the materials meet the project specification and that they are properly stored. Confirm 
that the faying surfaces have been properly prepared before the connections are assembled.  Observe the specified 
job site testing and calibration, and confirm that the procedure to be used provides the required tension.  Monitor 
the work to ensure the testing procedures are routinely followed on joints that are specified to be fully tensioned.</TXT><BRK/>
<BRK/>
<TXT>[Inspection by the Government will include proper preparation, size, gaging location, and acceptability of welds; 
identification marking; operation and current characteristics of welding sets in use; and calibration of torque 
wrenches for high-strength bolts.]</TXT><BRK/>
<BRK/>
<TXT>[The Contractor shall inspect proper preparation, size, gaging location, and acceptability of welds; identification 
marking; operation and current characteristics of welding sets in use; and calibration of torque wrenches for 
high-strength bolts.]</TXT><BRK/>
<BRK/>
<TXT>[Inspection of high-strength bolted connections by the Government will be performed in accordance with <RID>AISC 317</RID>
.]</TXT><BRK/>
<BRK/>
<TXT>[The Contractor shall inspect high-strength bolted connections in accordance with <RID>AISC 317</RID>.]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.9.4.3   Testing</TTL><BRK/>
<BRK/>
<TXT>The Government has the <TST>option to perform nondestructive tests on [5] [_____] percent of the installed bolts</TST> to 
verify compliance with pre-load bolt tension requirements.  The nondestructive testing will be done in-place 
using an ultrasonic measuring device or any other device capable of determining in-place pre-load bolt tension.  
The test locations shall be selected by the Contracting Officer.  If more than [10] [_____] percent of the bolts 
tested contain defects identified by testing, then all bolts used from the batch from which the tested bolts 
were taken, shall be tested.  Retest new bolts after installation.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT>[<TTL>3.9.5   Testing for Embrittlement</TTL><BRK/>
<BRK/>
<TXT><TST><RID>ASTM A 143/A 143M</RID> for steel products hot-dip galvanized after fabrication.</TST></TXT><BRK/>
<BRK/>
]</SPT></SPT><SPT><TTL>3.10   SPECIAL INSPECTION AND TESTING FOR SEISMIC-RESISTING SYSTEMS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Include this paragraph <HL1>only</HL1> when special inspection and testing for seismic-resisting 
systems is required by paragraph 3.2 of FEMA 302, NEHRP RECOMMENDED PROVISIONS 
FOR SEISMIC REGULATIONS FOR NEW BUILDINGS AND OTHER STRUCTURES.</NPR><BRK/>
<BRK/>
<NPR>This paragraph will be applicable to both new buildings designed according to 
TI 809-04, SEISMIC DESIGN FOR BUIDLINGS, and the existing building seismic rehabilitation 
designs done according to TI 809-05, SEISMIC EVALUATION AND REHABILITATION FOR 
BUILDINGS.</NPR><BRK/>
<BRK/>
<NPR>The designer must indicate on the drawings all locations and all features for 
which special inspection and testing is required in accordance with Chapter 
3 of FEMA 302.  This includes indicating the locations of all structural components 
and connections requiring inspections.</NPR><BRK/>
<BRK/>
<NPR>Add any additional requirements as necessary</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<NED/><TXT>Special inspections and testing for seismic-resisting systems and components shall be done in accordance with 
Section <SRF>01 45 35</SRF> SPECIAL INSPECTION FOR SEISMIC-RESISTING SYSTEMS.</TXT><BRK/>
<BRK/></SPT>
</PRT>    <END/><BRK/></SEC>