<SCN>SECTION 10 14 02</SCN><BRK/>
<BRK/>
<STL>INTERIOR SIGNAGE</STL><BRK/>
<DTE>02/09</DTE><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This guide specification covers the requirements for <SCP>common types of 
signs, dimensional letters, and metal plaques used inside buildings</SCP>.<BRK/>
<BRK/>
Edit this guide specification for project specific requirements by adding, deleting, 
or revising text.  For bracketed items, choose applicable items(s) or insert 
appropriate information.<BRK/>
<BRK/>
Remove information and requirements not required in respective project, whether 
or not brackets are present.<BRK/>
<BRK/>
Comments and suggestions on this guide specification are welcome and should 
be directed to the technical proponent of the specification.  A listing of <URL HREF="http://65.204.17.188/report/ufgs.html">technical 
proponents</URL>, including their organization designation and telephone number, is 
on the Internet.<BRK/>
<BRK/>
Recommended changes to a UFGS should be submitted as a <URL HREF="http://65.204.17.188/projnet/cms/public.html">Criteria Change Request 
(CCR)</URL>.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<PRT><TTL>PART 1   GENERAL</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This section covers some of the more common interior sign types.  When 
other sign types are to be used, specifications will be modified accordingly.  
Buildings will be accessible in accordance with 36 CFR, Part 1191, Americans 
with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities 
except for Army buildings excluded by TI 800-01 Design Criteria.</NPR><BRK/>
<BRK/>
<NPR>In combination with this specification, drawings and attachments will include 
location, dimensions, elevations, schedules, content, details and such other 
information as required to indicate the extent of the work.  The same terminology 
and designations used in the specification will be used on the drawings, schedules 
and attachments.</NPR><BRK/>
<BRK/>
<NPR>Product selections shall be based on quality, aesthetic values, appearance, 
and cost as related to project needs.</NPR><BRK/>
<BRK/>
<NPR>Use of personal names in interior signage is discouraged.  If personal names 
are required, changeable message strips will be used.  Consider coordination 
of interior signage within this specification with signage required on individual 
workstations which is specified in Section <SRF>12 50 00</SRF> FURNITURE SYSTEMS.</NPR><BRK/>
<BRK/>
<NPR>Interior stairwell signage will be provided in accordance with Life Safety Code 
NFPA 101, Chapter 5, and applicable occupancy chapters.  Clearly define interstitial 
spaces or other doorways within stairwell that do not lead to a horizontal exitway 
with signage that states "Not an Exit".</NPR><BRK/>
<BRK/>
<NPR>Permanent information on room identification signs includes the room number 
on all room identification signs, symbol and message on toilet rooms, message 
on janitor closets, mechanical/electrical and communications rooms, and message 
on stairs.</NPR><BRK/>
<BRK/>
<NPR>Where appropriate for medical facilities, include the following requirements 
for signage:<BRK/>
<BRK/>
1.  Room numbering for spaces within the medical facility will be determined 
jointly by the using facility and the design team.  User room number will be 
different than architectural room number (see MIL-HDBK 1191, 4.15.3).  Room 
numbering will be consistent throughout the facility.  For inpatient medical 
facilities, rooms with audiovisual nurse call shall have a unique user room 
number, since audiovisual nurse call is tied into a digital paging system.  
For outpatient clinics, rooms with tonevisual nurse call, do not need a unique 
user room number, since tonevisual nurse call is hardwired to a panel located 
at a nursing station.  Room numbering should address the following issues:<BRK/>
<BRK/>
     a.  Wayfinding within clinics and other departments (user room #).<BRK/>
<BRK/>
     b.  Facility Maintenance (architectural room #).<BRK/>
<BRK/>
     c.  Audiovisual Nurse Call (inpatient) (unique user room #).<BRK/>
<BRK/>
     d.  Tonevisual Nurse Call (outpatient) (user room #).<BRK/>
<BRK/>
2.  The use of symbols/graphics on interior signage will be limited.  International 
symbols and graphics will be used where needed.  Recommended symbols include 
men/women symbol for toilet rooms and showers, men/women symbol with key for 
locker rooms, telephone symbol for public telephone areas,   information (?), 
radiation symbol, biohazard symbol, and handicap symbol.<BRK/>
<BRK/>
3.  Arrow placement order on interior signage will comply with MIL-HDBK 1191, 
4.15.2.2.  Left pointing arrows at top of sign, followed by up pointing arrows, 
then right pointing arrows at bottom of sign.  Example follows:<BRK/>
<BRK/>
            &lt; EMERGENCY<BRK/>
            ^ Orthopedic Clinic<BRK/>
            &gt; Admissions<BRK/>
<BRK/>
4.  Signage schedule should be provided in electronic spreadsheet format.  Schedule 
will include architectural room number, user room number, type of sign, message, 
symbol (if needed), color, and mounting location.<BRK/>
<BRK/>
5.  Building directories and accompanying orientation maps for the medical facility 
will be determined jointly by the using facility and the design team.  Orientation 
maps, if required, will be included as part of the interior signage package, 
and should be of the same manufacturer.  Include international symbols for information 
(?), parking areas (upper case P within circle), public toilet rooms, public 
telephones, and graphic north arrow on orientation maps.  Orientation map is 
to be positioned so that building left is viewer's left.<BRK/>
<BRK/>
6.  Large, easy to read signs over reception counters, check-in counters, information 
desks, or departments will be provided.  Signs should be either ceiling mounted 
or affixed to soffit directly above counters.<BRK/>
<BRK/>
7.  Room identification signs should be 20.32 cm x 20.32 cm (8 x 8 inch) or 
22.86 cm x 22.22.86 cm (9 x 9 inch).  Justification of room number and message 
will be flush left.<BRK/>
<BRK/>
8.  Fire evacuation signs will be provided in accordance with the local Fire 
Marshal, if required.<BRK/>
<BRK/>
9.  Overhead directional signs should not block fire exit signs.<BRK/>
<BRK/>
10.  Signage will clearly define all staff, public, or patient toilet rooms.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>1.1   REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This paragraph is used to list the publications cited in the text of 
the guide specification. The publications are referred to in the text by basic 
designation only and listed in this paragraph by organization, designation, 
date, and title.<BRK/>
<BRK/>
Use the Reference Wizard's Check Reference feature when you add a RID outside 
of the Section's Reference Article to automatically place the reference in the 
Reference Article.  Also use the Reference Wizard's Check Reference feature 
to update the issue dates.<BRK/>
<BRK/>
References not used in the text will automatically be deleted from this section 
of the project specification when you choose to reconcile references in the 
publish print process.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The publications listed below form a part of this specification to the extent referenced.  The publications are 
referred to in the text by basic designation only.</TXT><BRK/>
<BRK/>
<REF><ORG>ALUMINUM ASSOCIATION (AA)</ORG><BRK/><BRK/><RID>AA DAF-45</RID><RTL>(2003) Designation System for Aluminum Finishes</RTL><BRK/><BRK/><RID>AA PK-1</RID><RTL>(2008) Pink Sheets: Designations and Chemical Composition Limits for Aluminum Alloys in the Form of Castings and Ingot</RTL><BRK/><BRK/></REF><REF><ORG>AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)</ORG><BRK/><BRK/><RID>AAMA 2604</RID><RTL>(2005) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels</RTL><BRK/><BRK/></REF><REF><ORG>AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)</ORG><BRK/><BRK/><RID>ANSI Z97.1</RID><RTL>(2004) Safety Glazing Materials Used in Buildings</RTL><BRK/><BRK/></REF><REF><ORG>AMERICAN WELDING SOCIETY (AWS)</ORG><BRK/><BRK/><RID>AWS D1.2/D1.2M</RID><RTL>(2008) Structural Welding Code - Aluminum</RTL><BRK/><BRK/></REF><REF><ORG>ASTM INTERNATIONAL (ASTM)</ORG><BRK/><BRK/><RID>ASTM B 209</RID><RTL>(2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate</RTL><BRK/><BRK/><RID>ASTM B 209M</RID><RTL>(2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)</RTL><BRK/><BRK/><RID>ASTM B 221</RID><RTL>(2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes</RTL><BRK/><BRK/><RID>ASTM B 221M</RID><RTL>(2007) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)</RTL><BRK/><BRK/><RID>ASTM C 1036</RID><RTL>(2006) Standard Specification for Flat Glass</RTL><BRK/><BRK/><RID>ASTM D 635</RID><RTL>(2006) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position</RTL><BRK/><BRK/></REF><REF><ORG>NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)</ORG><BRK/><BRK/><RID>NFPA 70</RID><RTL>(2007; AMD 1 2008) National Electrical Code - 2008 Edition</RTL><BRK/><BRK/></REF><REF><ORG>U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)</ORG><BRK/><BRK/><RID>36 CFR 1191</RID><RTL>Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities</RTL><BRK/><BRK/></REF></SPT><SPT><TTL>1.2   SUBMITTALS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL 
PROCEDURES and edit the following list to reflect only the submittals required 
for the project.  Submittals should be kept to the minimum required for adequate 
quality control.<BRK/>
<BRK/>
A “G” following a submittal item indicates that the submittal requires Government 
approval.  Some submittals are already marked with a “G”.  Only delete an existing 
“G” if the submittal item is not complex and can be reviewed through the Contractor’s 
Quality Control system.  Only add a “G” if the submittal is sufficiently important 
or complex in context of the project.<BRK/>
<BRK/>
For submittals requiring Government approval on Army projects, a code of up 
to three characters within the submittal tags may be used following the "G" 
designation to indicate the approving authority.  Codes for Army projects using 
the Resident Management System (RMS) are:  "AE" for Architect-Engineer; "DO" 
for District Office (Engineering Division or other organization in the District 
Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project 
Office.  Codes following the "G" typically are not used for Navy, Air Force, 
and NASA projects.<BRK/>
<BRK/>
Choose the first bracketed item for Navy, Air Force and NASA projects, or choose 
the second bracketed item for Army projects.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Government approval is required for submittals with a "G" designation; submittals not having a "G" designation 
are for [Contractor Quality Control approval.][information only.  When used, a designation following the "G" 
designation identifies the office that will review the submittal for the Government.]  The following shall be 
submitted in accordance with Section <SRF>01 33 00</SRF> SUBMITTAL PROCEDURES:</TXT><BRK/>
<BRK/>
<LST><SUB>SD-02 Shop Drawings</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Detail Drawings</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  Drawings showing elevations of each type of sign, dimensions, details and methods of mounting 
or anchoring, mounting height, shape and thickness of materials, and details of construction.  
A schedule showing the location, each sign type, and message shall be included.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-03 Product Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Installation</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  Manufacturer's descriptive data, catalogs cuts, installation and cleaning instructions.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-04 Samples</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Interior Signage</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  One sample of each of the following sign types showing typical quality, workmanship and color.  
The samples may be installed in the work, provided each sample is identified and location recorded.</ITM><BRK/>
<BRK/>
<ITM>  a.  Directional sign.</ITM><BRK/>
<BRK/>
<ITM>  b.  Standard Room sign.</ITM><BRK/>
<BRK/>
<ITM>  c.  Changeable message strip sign.</ITM><BRK/>
<BRK/>
<ITM>  d.  [_____].</ITM><BRK/>
<BRK/>
<ITM><SUB>Software</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  [One][_____] copy of the software for user produced signs</ITM><BRK/>
<BRK/>
<LST><SUB>SD-10 Operation and Maintenance Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Approved Manufacturer's Instructions</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<ITM><SUB>Protection and Cleaning</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  [Six][_____] copies of operating instructions outlining the step-by-step procedures required 
for system operation shall be provided.  The instructions shall include simplified diagrams 
for the system as installed.  [Six][_____] copies of maintenance instructions listing routine 
procedures, repairs, and guides shall be provided.  The instructions shall include the manufacturer's 
name, model number, service manual, parts list, and brief description of all equipment and their 
basic operating features.  Each set shall be permanently bound and shall have a hard cover.  
The following identification shall be inscribed on the covers:  the words "OPERATING AND MAINTENANCE 
INSTRUCTIONS", name and location of the facility, name of the Contractor, and contract number.</ITM><BRK/>
<BRK/></SPT>
<SPT><TTL>1.3   GENERAL</TTL><BRK/>
<BRK/>
<TXT><SUB>Interior signage</SUB> shall be of the design, detail, sizes, types, and message content shown on the drawings/attachments/signage 
placement schedule (as applicable), shall conform to the requirements specified, and shall be provided at the 
locations indicated.  Signs shall be complete with lettering, framing as detailed, and related components for 
a complete installation.  Signage shall be obtained from a single manufacturer with edges and corners of finished 
letterforms and graphics true and clean.  Recyclable materials shall conform to EPA requirements in accordance 
with Section <SRF>01 62 35</SRF> RECYCLED / RECOVERED MATERIALS.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.4   QUALIFICATIONS</TTL><BRK/>
<BRK/>
<TXT>Signs, plaques, and dimensional letters shall be the standard product of a manufacturer regularly engaged in 
the manufacture of such products and shall essentially duplicate signs that have been in satisfactory use at 
least 2 years prior to bid opening.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.5   DELIVERY AND STORAGE</TTL><BRK/>
<BRK/>
<TXT>Materials shall be packaged to prevent damage and deterioration during shipment, handling, storage and installation.  
Product shall be delivered to the jobsite in manufacturer's original packaging and stored in a clean, dry area 
in accordance with manufacturer's instructions.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.6   EXTRA STOCK</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  A sufficient number of identification signs and letters for future use 
for changes and message replacement shall be specified.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The Contractor shall provide [_____] extra frames and extra stock of the following:  [[_____] blank plates of 
each color and size for sign types [_____].][  [_____] pressure-sensitive letters in each color and size for 
sign type [_____].][  [_____] changeable message strips for sign type [_____].][  Provide [[_____] paper inserts 
and <SUB>software</SUB> for creating text and symbols for [IBM compatible][Macintosh][_____] computers for Owner production 
of paper inserts after project completion.][equipment necessary for removal of signage parts and pieces.]]</TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 2   PRODUCTS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Delete signage systems, directories, etc., not required for project.  
Coordinate electrical requirements with Division 16 and available electric service.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>2.1   ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Depending on the complexity of the project consider a modular signage 
system such as structural rails and end caps.  Coordinate project requirements 
and specific signage system with user.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>2.1.1   Standard Room Signs</TTL><BRK/>
<BRK/>
<TXT>Signs shall consist of [acrylic plastic<MET> 2 mm</MET><ENG> 0.080 inch</ENG> thickness minimum conforming to <RID>ANSI Z97.1</RID>][laminated 
thermosetting Type MP plastic (three-ply melamine plastic laminate with phenolic core)][6063-T5 extruded aluminum 
in accordance with<MET> <RID>ASTM B 221M</RID></MET><ENG> <RID>ASTM B 221</RID></ENG> and<MET> <RID>ASTM B 209M</RID></MET><ENG> <RID>ASTM B 209</RID></ENG>][_____] and shall conform to the following:  <BRK/>
<BRK/>
[Frames shall be [aluminum][wood][molded acrylic]]. [Frames shall be [<MET>3 mm</MET><ENG> 1/8 inch</ENG>][<MET>6 mm</MET><ENG> 1/4 inch</ENG>][_____] wide.]<BRK/>
<BRK/>
[End caps shall be [aluminum][wood][molded acrylic] with [round][square][_____style] corners.]<BRK/>
<BRK/>
[Units shall be frameless. Corners of signs shall be [squared][rounded to<MET> [10] [13] [19] [_____] mm</MET><ENG> [3/8] [1/2] 
[3/4] [_____] inch</ENG> radius].]</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.2   Changeable Message Strip Signs</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  </NPR><NPR>The insert preparation method most appropriate to each building should 
be chosen, and the same method should be used consistently throughout the building.  
Requirements for sign-making equipment or software will be determined jointly 
by the using facility and the designer.  If using other than standard paper, 
require extra stock be provided.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Changeable message strip signs shall be of same construction as standard room signs to include a clear sleeve 
that will accept a paper or plastic insert identifying changeable text.  The insert shall be prepared [die-cut 
vinyl letters applied to<MET> 0.38 mm</MET><ENG> 0.015 inch</ENG> rigid vinyl film][dry transfer letters applied to paper card stock][typeset 
message photographically enlarged to size and mounted on paper card stock][typewritten message photographically 
enlarged or used at actual size][_____].[  Provide[ paper and] software for creating text and symbols for [IBM 
compatible][Macintosh][_____] computers for Owner production of paper inserts after project completion.] [Sliding 
inserts or slide knobs that slide horizontally exposing different graphic information shall be provided as identified 
in the signage placement schedule and [drawings][attachments.]]  </TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.3   Type of Mounting For Signs</TTL><BRK/>
<BRK/>
<TXT>Extruded aluminum brackets shall be provided for hanging, projecting, and double-sided signs.  Mounting for framed, 
hanging, and projecting signs shall be by mechanical fasteners.  Surface mounted signs shall be mounted with 
[<MET>1.6 mm</MET><ENG> 1/16 inch</ENG> thick vinyl foam tape][countersunk mounting holes in plaques and mounting screws][magnetic 
tape [silicone adhesive]] [_____] fabricated from materials that are not corrosive to sign material and mounting 
surface.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.4   Graphics</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Edit the following requirements as necessary for the project.  Graphics 
methods that are easily vandalized such as vinyl first surface copy and acrylic 
characters bonded to acrylic shall not be permitted.  The silkscreened first 
surface copy  method is generally used for mass produced signs.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Signage graphics for modular signs shall conform to the following:</TXT><BRK/>
<BRK/>
<LST>[Subsurface copy:  Copy is transferred to the back face of clear acrylic sheeting forming the panel face 
to produce precisely formed opaque image.  This method bonds all sign elements (color, graphics, lettering, 
braille and substrate) into a single unit.]</LST><BRK/>
<BRK/>
<LST>[Silkscreened First Surface Copy (non-tactile):  Message shall be applied to panel using the silkscreen 
process.  Silkscreened images shall be executed with photo screens prepared from original art.  Handcut 
screens will not be accepted.  Original art shall be defined as artwork that is a first generation reproduction 
of the specified art.  Edges and corners shall be clean.]</LST><BRK/>
<BRK/>
<LST>[Surface Applied Photopolymer:  Integral graphics and braille achieved by photomechanical stratification 
processes.  Photopolymer used for ADA compiant graphics shall be of the type that has a minimum durometer 
reading of 90.  Tactile graphics shall be raised<MET> 0.8 mm</MET><ENG> 1/32 inch</ENG> from the first surface of plaque by 
photomechanical stratification process.]</LST><BRK/>
<BRK/>
<LST>[Engraved Copy:  Machine engrave letters, numbers, symbols, and other graphics into panel sign on face 
to produce precisely formed copy and sharp images, incised to uniform depth.  Melamine plastic engraving 
stock used for ADA compliant graphic shall be three-ply lamination contrasting color core meeting <RID>ASTM D 635</RID>
]</LST><BRK/>
<BRK/>
<LST>[Graphic Blast Raised Copy:  Background is sandblasted to a uniform depth of<MET> 0.8 mm</MET><ENG> 1/32 inch</ENG> leaving 
raised text and Braille.  Background shall be painted with polyurethane paint.]<BRK/>
<BRK/>
[Embossed:  Methods other than sandblasting such as vacuum formed to create ADA compliant projected graphics.]</LST><BRK/>
<BRK/>
<LST>[[Cast][Fabricated][Solid] Aluminum Letters: <MET>[3] [6] [_____] mm</MET><ENG> [1/8] [1/4][_____] inch</ENG> thick shall be 
provided and fastened to the message panel with concealed fasteners.]</LST><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.5   Character Proportions and Heights</TTL><BRK/>
<BRK/>
<TXT>Letters and numbers on signs conform to <RID>36 CFR 1191</RID>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.6   Raised and Braille Characters and Pictorial Symbol Signs (Pictograms)</TTL><BRK/>
<BRK/>
<TXT>Raised letters and numbers on signs shall conform to <RID>36 CFR 1191</RID>.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2   BUILDING DIRECTORIES</TTL><BRK/>
<BRK/>
<TXT>Building directories shall be lobby directories or floor directories, and shall be provided with a changeable 
directory listing consisting of the areas, offices and personnel located within the facility.  Dimensions, details, 
and materials of sign and message content shall be as shown on the [drawings][attachments][and signage placement 
schedule].</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.1   Header Panel</TTL><BRK/>
<BRK/>
<TXT>Header panel shall [have background metal to match frame and shall have raised letters][be acrylic with raised 
acrylic letters][be ES/MP plastic with raised letters][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.2   Doors</TTL><BRK/>
<BRK/>
<SPT><TTL>2.2.2.1   Door Glazing</TTL><BRK/>
<BRK/>
<TXT>Door glazing shall be [in accordance with <RID>ASTM C 1036</RID>, Type 1, Class 1, Quality 3, minimum<MET> 3 mm</MET><ENG> 1/8 inch</ENG> thick][clear 
acrylic sheet<MET> 4.8 mm</MET><ENG> 3/16 inch</ENG> thick conforming to [_____]][clear polycarbonate sheet<MET> 4.8 mm</MET><ENG> 3/16 inch</ENG> thick][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.2.2   Door Construction</TTL><BRK/>
<BRK/>
<TXT>Extruded aluminum door frame shall be of same finish as surrounding frame.  Corners shall be mitered [, reinforced][, 
welded], and assembled with concealed fasteners.  Hinges shall be standard with the manufacturer, in finish to 
match frames and trim.  Glazing shall be set in frame with resilient glazing channels.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.2.3   Door Locks</TTL><BRK/>
<BRK/>
<TXT>Door locks shall be manufacturer's standard, and shall be keyed alike.  Provide two sets of keys.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.3   Fabrication</TTL><BRK/>
<BRK/>
<TXT>Extruded aluminum frames and trim shall be assembled with corners [reinforced][welded] and mitered to a hairline 
fit, with no exposed fasteners.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.4   Illuminated Units</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Coordinate illumination with Division 16 and available electric service.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Illuminated directory units shall have concealed internal [top][back] lighting with [rapid start fluorescent 
tube lamp][_____], internal wiring, and lead at wire for connection.  Electrical work shall comply with <RID>NFPA 70</RID>
 and shall be UL or FM listed.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.5   Negative Graphics Directory System</TTL><BRK/>
<BRK/>
<TXT>Directory shall consist of internally illuminated unit with backlit photo negative directory strips and a black 
background.  Unit shall have a tinted [tempered safety solar glass][_____] door.  Design of unit shall be as 
shown.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.5.1   Construction</TTL><BRK/>
<BRK/>
<TXT>The directory shall be constructed of an aluminum<MET> [100] [150] mm</MET><ENG> [4] [6] inch</ENG> deep frame with satin [black][dark 
bronze][_____] anodized finish.  Unit shall be [[semi][fully] recessed][[pedestal][_____]] mounted.  Unit shall 
have a<MET> [75] [_____] mm</MET><ENG> [3] [_____] inch</ENG> high header lettering as shown.  Unit shall have a [_____]<MET> 9.3 mm</MET><ENG> 3/8 
inch</ENG> face door frame with concealed hinges and locking system.  Door frame shall be [aluminum with [satin][black][dark 
bronze]][solid [polished][satin][chrome plated] brass] [solid architectural bronze][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.5.2   Message Strips</TTL><BRK/>
<BRK/>
<TXT>Message strips shall be photo negative type updatable by user.  Message strips shall be [as shown on the drawings][_____].</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.6   Changeable Letter/Message Strip Directory System</TTL><BRK/>
<BRK/>
<TXT>Directory shall consist of [an internally illuminated][a non-illuminated] unit with [step or groove, laser or 
rotary engraved removable name strips] [felt grooved for changeable letters][cast vinyl to receive molded changeable 
letter tiles][laminated plastic magnetic back message strips].  Design of unit shall be as shown in the drawings.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.6.1   Construction</TTL><BRK/>
<BRK/>
<TXT>The directory shall be constructed of an aluminum<MET> [50] [_____] mm</MET><ENG> [2] [_____] inch</ENG> deep frame with satin [black][dark 
bronze][_____] anodized finish.  Unit shall be [surface][[semi] [fully] recessed][[pedestal] [_____]] mounted.  
Unit shall have a<MET> [75] [_____] mm</MET><ENG> [3] [_____] inch</ENG> high header with lettering as shown.  Unit shall have a<MET> [9.3] 
[_____] mm</MET><ENG> [3/8] [_____] inch</ENG> face [[concealed hinge door and locking system][lift off frame]] with [[tempered 
safety glass][_____]][fixed frame][_____].  Door frame shall be [aluminum with satin [black][dark bronze]][solid 
[polished] [satin][chrome plated] brass][solid architectural bronze][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.6.2   Message Strips</TTL><BRK/>
<BRK/>
<TXT>[Namestrips shall be updatable by user.  Namestrips shall be [[acrylic][_____]][sized in accordance with manufacturer's 
standard][_____].] [Namestrips shall be felt grooved background with changeable upper and lower case [Helvetica 
Medium][_____] letters.  Tabbed vinyl letters and numbers shall be provided in accordance with the [drawings][ 
and ][schedule].]</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2.7   Touchscreen Electronic Directory System</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  The touchscreen electronic directory system is a limited usage item and 
must be fully justified prior to being specified.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Touchscreen electronic directory system shall be a complete turnkey system consisting of touchscreen monitor, 
processor, update terminal with software connected through a [telephone network] [or] [local area network (LAN)].  
The system shall be in compliance with the layout and number shown.  Electrical equipment shall be UL listed 
and shall comply with <RID>NFPA 70</RID>.  Unit shall be [free-standing][wall mounted].</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.7.1   Directory Unit</TTL><BRK/>
<BRK/>
<TXT>Directory unit shall consist of [[1][_____]]<MET> [350] [400] [_____] mm</MET><ENG> [14] [16] [_____] inch</ENG> touchscreen monitor 
and membrane keypad with [alphabetic 28][alphanumeric 38][alphabetic braille 30] keys.  Screen resolution shall 
be [SVGA [800 x 600][1280 x 1024]][_____].  Monitor shall be full color.  Processor shall be Pentium 75 or better 
with sound peripherals and have a listing capacity of [96,000][1,000,000][_____] items.  Directory unit shall 
be of design and finishes as shown.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.7.2   Update Terminal</TTL><BRK/>
<BRK/>
<TXT>Update terminal unit shall consist of a<MET> [300] [350] [_____] mm</MET><ENG> [12] [14] [_____] inch</ENG> color monitor with [84] 
[101] key keypad.  Unit shall have a 132 column report printer.  Unit shall include a Pentium 75 or better PC 
processor with floppy disk from update terminal to each directory.  System shall include [network from update 
to each directory] [and] [network from mainframe to update terminal to each directory].  Communications shall 
be over a telephone network or a LAN. </TXT><BRK/>
<BRK/></SPT>
</SPT></SPT><SPT><TTL>2.3   METAL PLAQUES</TTL><BRK/>
<BRK/>
<SPT><TTL>2.3.1   Cast Metal Plaques</TTL><BRK/>
<BRK/>
<SPT><TTL>2.3.1.1   Fabrication</TTL><BRK/>
<BRK/>
<TXT>Cast metal plaques shall have the logo, emblem and artwork cast in the [bas relief][flat relief][_____] technique.  
Plaques shall be fabricated from [prime aluminum][bronze][yellow brass].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.1.2   Border</TTL><BRK/>
<BRK/>
<TXT>Border shall be [flat band][plain edge][bevel][custom ornamental][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.1.3   Background</TTL><BRK/>
<BRK/>
<TXT>Background texture shall be [leather][fine pebble][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.1.4   Mounting</TTL><BRK/>
<BRK/>
<TXT>Mounting shall be [concealed][rosettes and anchors][rosettes and toggle bolts][invisible][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.1.5   Finish</TTL><BRK/>
<BRK/>
<TXT>Finishes shall consist of [aluminum light colored sandblasted background.  Letters shall be satin polished and 
entire plaque shall be sprayed with two coats of clear lacquer.][aluminum with background sprayed dark gunmetal 
colored lacquer.  Letters shall be satin polished and entire plaque sprayed with two coats clear lacquer.][bronze 
with dark finish oxidized background.  Letters shall be satin polished and entire plaque sprayed with two coats 
of clear lacquer.][[aluminum][bronze] with background sprayed with standard color.  Letters shall be satin polished.]</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.3.2   Chemically Etched Metal Plaques</TTL><BRK/>
<BRK/>
<SPT><TTL>2.3.2.1   Fabrication</TTL><BRK/>
<BRK/>
<TXT>Plaque shall be chemically [single-][double-] etched one-piece [brass] [bronze][zinc][magnesium][_____]<MET> [0.8128] 
[1.6256] [3.175] [6.35] mm</MET><ENG> [0.032] [0.064] [0.125] [0.250] inch</ENG> thick.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.2.2   Finish</TTL><BRK/>
<BRK/>
<TXT>[Single-etched raised areas shall be in [gold-tone][silver-tone] [bronze-tone] finish and recessed areas shall 
be colorfilled.] [Double-etched raised areas shall be [gold-tone][silver-tone] and recessed textured areas shall 
be [gold-tone][silver-tone] colorfilled.]</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.3.3   Frost and Surface Oxidized Plaques</TTL><BRK/>
<BRK/>
<SPT><TTL>2.3.3.1   Fabrication</TTL><BRK/>
<BRK/>
<TXT>Plaque shall be frosted and surface oxidized one-piece [anodized aluminum] [brass][bronze][stainless steel]<MET> [1.02] 
[3.175] mm</MET><ENG> [0.040] [0.125] inch</ENG> thick.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3.3.2   Finish</TTL><BRK/>
<BRK/>
<TXT>[Material finish shall be [satin][polished].] [Frosted areas shall be oxidized [black for aluminum or stainless 
steel] [or] [black or brown, for brass or bronze].]</TXT><BRK/>
<BRK/></SPT>
</SPT></SPT><SPT><TTL>2.4   DIMENSIONAL BUILDING LETTERS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  These letters are for direct application to interior building surfaces.  
Drawings must show mounting type details.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>2.4.1   Fabrication</TTL><BRK/>
<BRK/>
<TXT>Letters shall be fabricated from [[cast aluminum][cast bronze]][<MET>[2.29] [3.17] mm</MET><ENG> [0.090] [0.125] inch</ENG> aluminum 
sheet][extruded aluminum] [injection molded plastic].  Letters shall be cleaned by chemical etching or cleaned 
ultrasonically in a special degreasing bath.  Letters shall be packaged for protection until installation.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4.2   Typeface</TTL><BRK/>
<BRK/>
<TXT>Typeface shall be [helvetica medium][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4.3   Size</TTL><BRK/>
<BRK/>
<TXT>Letter size shall be[_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4.4   Finish</TTL><BRK/>
<BRK/>
<TXT>[Anodized aluminum][Baked enamel or two-component acrylic polyurethane] [[Polished][Oxidized] bronze with clear 
coat] finish shall be provided.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4.5   Mounting</TTL><BRK/>
<BRK/>
<TXT>[Threaded studs][Steel U-bracket, cap screws, and expansion bolts] of number and size recommended by manufacturer, 
shall be supplied for concealed anchorage.  Letters which project from the mounting surface shall have [stud 
spacer sleeves][_____].  Letters, studs, and sleeves shall be of the same material.  Templates for mounting shall 
be supplied.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.5   PRESSURE SENSITIVE LETTERS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Use pressure sensitive letters for direct application to building interior 
surfaces such as glass and doors.  Be sure surface of material will accept adhesion 
of letters.  Show locations, message content, sizes, and colors on drawings 
or in a message schedule.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Ensure that edges and corners of finished letterforms and graphics are true and clean.  Do not use letterforms 
and graphics with rounded positive or negative corners, nicked, cut, or ragged edges.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.5.1   Typeface</TTL><BRK/>
<BRK/>
<TXT>[Helvetica medium][_____].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.5.2   Size</TTL><BRK/>
<BRK/>
<TXT>[_____][As indicated].</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.6   ALUMINUM ALLOY PRODUCTS</TTL><BRK/>
<BRK/>
<TXT>Aluminum extrusions shall be at least<MET> 3 mm</MET><ENG> 1/8 inch</ENG> thick, and aluminum plate or sheet shall be at least<MET> 1.3 
mm</MET><ENG> 0.0508 inch</ENG> thick.  Extrusions shall conform to<MET> <RID>ASTM B 221M</RID></MET><ENG> <RID>ASTM B 221</RID></ENG>; plate and sheet shall conform to<MET> <RID>ASTM B 209M</RID></MET><ENG>
 <RID>ASTM B 209</RID></ENG>.  Where anodic coatings are specified, alloy shall conform to <RID>AA PK-1</RID> alloy designation 514.0.  Exposed 
anodized aluminum finishes shall be as shown.  Welding for aluminum products shall conform to <RID>AWS D1.2/D1.2M</RID>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.7   ANODIC COATING</TTL><BRK/>
<BRK/>
<TXT>Anodized finish shall conform to <RID>AA DAF-45</RID> as follows:</TXT><BRK/>
<BRK/>
<LST>[Clear (natural) designation AA-M10-C22-A31, Architectural Class II<MET> 0.010 mm</MET><ENG> 0.4 mil</ENG> or thicker.]</LST><BRK/>
<BRK/>
<LST>[Integral color anodized designation AA-M10-C22-A32, Architectural Class<MET> 0.010 to 0.018 mm</MET><ENG> 0.4 to 0.7 
mil</ENG>.]</LST><BRK/>
<BRK/>
<LST>[Electrolytically deposited color-anodized designation AA-M10-C22-A34, Architectural Class II<MET> 0.010 to 
0.018 mm</MET><ENG> 0.4 to 0.7 mil</ENG>.]</LST><BRK/>
<BRK/></SPT>
<SPT><TTL>2.8   ORGANIC COATING</TTL><BRK/>
<BRK/>
<TXT>Organic coating shall conform to <RID>AAMA 2604</RID>, with total dry film thickness not less than<MET> 0.030 mm</MET><ENG> 1.2 mils</ENG>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.9   FABRICATION AND MANUFACTURE</TTL><BRK/>
<BRK/>
<SPT><TTL>2.9.1   Factory Workmanship</TTL><BRK/>
<BRK/>
<TXT>Holes for bolts and screws shall be drilled or punched.  Drilling and punching shall produce clean, true lines 
and surfaces.  Exposed surfaces of work shall have a smooth finish and exposed riveting shall be flush.  Fastenings 
shall be concealed where practicable.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.9.2   Dissimilar Materials</TTL><BRK/>
<BRK/>
<TXT>Where dissimilar metals are in contact, the surfaces will be protected to prevent galvanic or corrosive action.</TXT><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Color shall be selected from manufacturer's standard colors and indicated 
in SECTION 09 06 90 COLOR SCHEDULE or identified in this specification only 
when the project is very simple and has minimal finishes.  Custom colors shall 
be limited due to additional cost and impact on future orders.<BRK/>
<BRK/>
Signage background color should be in high contrast with signage copy.  Dark 
background with light copy is preferred.<BRK/>
<BRK/>
When the government directs that color be located in the drawings a note shall 
be added that states:  "Where color is shown as being specific to one manufacturer, 
an equivalent color by another manufacturer may be submitted for approval.  
Manufacturers and materials specified are not intended to limit the selection 
of equal colors from other manufacturers.  The word "color" as used herein includes 
surface color and pattern."</NPR><BRK/>
<AST/><BRK/></NTE>
</SPT></SPT><SPT><TTL>2.10   COLOR, FINISH, AND CONTRAST</TTL><BRK/>
<BRK/>
<TXT>Color shall be [in accordance with Section <SRF>09 06 90</SRF> COLOR SCHEDULE][as indicated on the drawings][_____].  Finish 
of all signs shall be eggshell, matte, or other non-glare finish as required in handicapped-accessible buildings.  </TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 3   EXECUTION</TTL><BRK/>
<BRK/>
<SPT><TTL>3.1   <SUB>INSTALLATION</SUB></TTL><BRK/>
<BRK/>
<TXT>Signs shall be installed plumb and true and in accordance with <SUB>approved manufacturer's instructions</SUB> at locations 
shown on the [<SUB>detail drawings</SUB>][schedule below][attachments].  Mounting height and mounting location shall conform 
to <RID>36 CFR 1191</RID>. Required blocking shall be installed.  Signs on doors or other surfaces shall not be installed 
until finishes on such surfaces have been installed.  Signs installed on glass surfaces shall be installed with 
matching blank back-up plates in accordance with manufacturer's instructions.  [Illuminated signage shall be 
in conformance with the requirements of Section <SRF>26 51 00</SRF> INTERIOR LIGHTING.]</TXT><BRK/>
<TBL><BRK/>
<THD>[SIGNAGE PLACEMENT SCHEDULE:</THD><BRK/>
<BRK/>
[DOOR]<BRK/>
[ROOM]      SIGN<BRK/>
[NUMBER      TYPE      TEXT              INSERT(S)           SYMBOL/REMARKS]]<BRK/></TBL>
<BRK/>
<SPT><TTL>3.1.1   Anchorage</TTL><BRK/>
<BRK/>
<TXT>Anchorage shall be in accordance with approved manufacturer's instructions.  Anchorage not otherwise specified 
or shown shall include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; 
toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood.  
Exposed anchor and fastener materials shall be compatible with metal to which applied and shall have matching 
color and finish.  Where recommended by signage manufacturer, foam tape pads may be used for anchorage.  Foam 
tape pads shall be minimum<MET> 2 mm</MET><ENG> 1/16 inch</ENG> thick closed cell vinyl foam with adhesive backing.  Adhesive shall 
be transparent, long aging, high tech formulation on two sides of the vinyl foam.  Adhesive surfaces shall be 
protected with a<MET> 0.13 mm</MET><ENG> 5 mil</ENG> green flatstock treated with silicone.  Foam pads shall be sized for the signage 
in accordance with signage manufacturer's recommendations.  Signs mounted to painted gypsum board surfaces shall 
be removable for painting maintenance.  Signs mounted to lay-in ceiling grids shall be mounted with clip connections 
to ceiling tees.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.1.2   <SUB>Protection and Cleaning</SUB></TTL><BRK/>
<BRK/>
<TXT>The work shall be protected against damage during construction.  Hardware and electrical equipment shall be adjusted 
for proper operation.  Glass, frames, and other sign surfaces shall be cleaned at completion of sign installation 
in accordance with the manufacturer's approved instructions.</TXT><BRK/>
<BRK/></SPT>
</SPT></PRT>     <END/><BRK/></SEC>