<?xml version="1.0" encoding="windows-1252"?><SEC xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://si.ksc.nasa.gov/sidownloads/xml/specsintactSEC.xsd"><MTA NAME="SUBFORMAT" CONTENT="NEW"/><HDR><AST/><BRK/>
USACE / NAVFAC / AFCESA / NASA      UFGS-11 42 00 (January 2008)<BRK/>
                                    -------------------------------------<BRK/>
Preparing Activity:  <PRA>NAVFAC</PRA>         Superseding<BRK/>
                                    UFGS-11 40 00.00 20 (April 2006)<BRK/>
                                    UFGS 11 46 01.00 10 (April 2006)<BRK/>
<BRK/>
<HL4>UNIFIED FACILITIES GUIDE SPECIFICATIONS</HL4><BRK/>
<BRK/>
<HL4>References are in agreement with UMRL dated January 2009</HL4><BRK/>
<AST/><BRK/></HDR>
<BRK/>
<SCN>SECTION 11 42 00</SCN><BRK/>
<BRK/>
<STL>FOOD PREPARATION EQUIPMENT</STL><BRK/>
<DTE>01/08</DTE><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This guide specification covers the requirements for <SCP>non-heated, non-refrigerated 
equipment used for food preparation other than cooking and baking</SCP>, such as prep 
tables and units, carts, racks, shelving, blenders, coffee makers, grinders, 
juicers, mixers, peelers, slicers, etc..<BRK/>
<BRK/>
Edit this guide specification for project specific requirements by adding, deleting, 
or revising text.  For bracketed items, choose applicable items(s) or insert 
appropriate information.<BRK/>
<BRK/>
Remove information and requirements not required in respective project, whether 
or not brackets are present.<BRK/>
<BRK/>
Comments and suggestions on this guide specification are welcome and should 
be directed to the technical proponent of the specification.  A listing of <URL HREF="http://65.204.17.188/report/ufgs.html">technical 
proponents</URL>, including their organization designation and telephone number, is 
on the Internet.<BRK/>
<BRK/>
Recommended changes to a UFGS should be submitted as a <URL HREF="http://65.204.17.188/projnet/cms/public.html">Criteria Change Request 
(CCR)</URL>.<BRK/>
<BRK/>
This guide specification includes tailoring options for NAVFAC and USACE.  Selection 
or deselection of a tailoring option will include or exclude that option in 
the section, but editing the resulting section to fit the project is still required.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Coordinate this section and use in conjunction with the following sections:<BRK/>
<BRK/>
<SRF>11 05 40</SRF> - COMMON WORK RESULTS FOR FOODSERVICE EQUIPMENT<BRK/>
<SRF>11 06 40.13</SRF> - FOOD SERVICE EQUIPMENT SCHEDULE</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<PRT><TTL>PART 1   GENERAL</TTL><BRK/>
<BRK/>
<SPT><TTL>1.1   REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This paragraph is used to list the publications cited in the text of 
the guide specification. The publications are referred to in the text by basic 
designation only and listed in this paragraph by organization, designation, 
date, and title.<BRK/>
<BRK/>
Use the Reference Wizard's Check Reference feature when you add a RID outside 
of the Section's Reference Article to automatically place the reference in the 
Reference Article.  Also use the Reference Wizard's Check Reference feature 
to update the issue dates.<BRK/>
<BRK/>
References not used in the text will automatically be deleted from this section 
of the project specification when you choose to reconcile references in the 
publish print process.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The publications listed below form a part of this specification to the extent referenced.  The publications are 
referred to within the text by the basic designation only.</TXT><BRK/>
<BRK/>
<REF><ORG>ASME INTERNATIONAL (ASME)</ORG><BRK/><BRK/><RID>ASME A112.19.3</RID><RTL>(2008) Stainless Steel Plumbing Fixtures (Designed for Residential Use)</RTL><BRK/><BRK/></REF><REF><ORG>NSF INTERNATIONAL (NSF)</ORG><BRK/><BRK/><RID>NSF 2</RID><RTL>(2008) Food Equipment</RTL><BRK/><BRK/><RID>NSF 59</RID><RTL>(2002e) Standard for Food Carts</RTL><BRK/><BRK/><RID>NSF 8</RID><RTL>(2007) Standard for Commercial Powered Food Preparation Equipment</RTL><BRK/><BRK/><RID>NSF Product Listing</RID><RTL>(2002)  NSF Product Listings of Food Equipment and Related Products, Components, and Materials</RTL><BRK/><BRK/></REF><REF><ORG>U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA)</ORG><BRK/><BRK/><RID>Energy Star</RID><RTL>(1992; R 2006) Energy Star Energy Efficiency Labeling System</RTL><BRK/><BRK/></REF><REF><ORG>U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)</ORG><BRK/><BRK/><RID>29 CFR 1910-SUBPART D</RID><RTL>Walking - Working Surfaces</RTL><BRK/><BRK/><RID>29 CFR 1910.144</RID><RTL>Safety Color Code for Marking Physical Hazards</RTL><BRK/><BRK/><RID>29 CFR 1910.145</RID><RTL>Accident Prevention Signs and Tags</RTL><BRK/><BRK/><RID>29 CFR 1910.212</RID><RTL>Safety Standard for Machinery and Machine Guarding</RTL><BRK/><BRK/><RID>29 CFR 1910.306</RID><RTL>Specific Purpose Equipment and Installations</RTL><BRK/><BRK/></REF></SPT><SPT><TTL>1.2   GENERAL REQUIREMENTS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Indicate the configuration and layout for all food preparation equipment, 
with interior elevations and equipment identified by number.  Show "Food Service 
Equipment Schedule" on the drawings using the same identification numbers<TAI OPT="USACE">[ as 
indicated on the current US Army Quartermaster Center and School equipment schedule]</TAI>
.  Ensure that all Contractor built-to-order items, per Food Service Equipment 
Schedule", are shown and coordinated with the specifications.</NPR><BRK/>
<BRK/>
<NPR>Designer must coordinate with other sections, including 11 05 40 - COMMON WORK 
RESULTS FOR FOODSERVICE EQUIPMENT and 11 06 40.13 - FOODSERVICE EQUIPMENT SCHEDULE 
for general requirements and final connection of equipment.</NPR><BRK/>
<BRK/>
<TAI OPT="NAVFAC"><NPR>NOTE:  Details of particular equipment and installations are provided on Naval 
Food Service Division drawings.  Use these NAVFSD drawings as a basis for the 
project details.  Contact NAVFSD at commercial telephone (717) 790-7580 or DSN 
430-7580.</NPR></TAI><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Refer to section <SRF>11 05 40</SRF> - COMMON WORK RESULTS FOR FOODSERVICE EQUIPMENT for general requirements.  Provide 
detailed schedule  as specified in section <SRF>11 06 40.13</SRF> for FOODSERVICE EQUIPMENT SCHEDULE.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.3   DESCRIPTION OF WORK</TTL><BRK/>
<BRK/>
<TXT>The work includes [furnishing and] [installing] [and modifying existing]  food service preparation equipment 
and related work.  Verify all existing dimensions, contract drawings, product data and all related conditions 
prior to commencing rough-in work.  Include coordination of delivery through existing finished opening and vertical 
handling limitations within the building.  Advise the Contracting Officer of all discrepancies prior to ordering 
equipment.  Submit <SUB>Contractor's Field Verification Data</SUB> prior to the preconstruction meeting.</TXT><BRK/>
<BRK/>
<TXT>Provide rough-in and connect utilities to equipment in accord with requirements specified in other sections of 
this specification and in accord with the physical dimensions, capacities, manufacturer's instructions, and other 
requirements of the equipment furnished.</TXT><BRK/>
<BRK/>
<SPT><TTL>1.3.1   Design Requirements</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  On the drawings, show:</NPR><BRK/>
<BRK/>
<NPR>1.  A<MET> 1:50</MET><ENG> 1/4 inch</ENG> scale floor plan with layout of all food service equipment<TAI OPT="NAVFAC">
 and Naval Equipment Symbols</TAI>.</NPR><BRK/>
<BRK/>
<NPR>2.  Food Service Equipment Schedule laid out in accord with <TAI OPT="NAVFAC">NAVFSSO</TAI><TAI OPT="USACE">current US 
Army Quartermaster Center and School equipment schedule</TAI> specified design requirements, 
including Energy Star qualified model list.</NPR><BRK/>
<BRK/>
<NPR>3.  Floor, wall, and ceiling penetrations.</NPR><BRK/>
<BRK/>
<NPR>4.  Raised bases, retainer curbs, or depressions.</NPR><BRK/>
<BRK/>
<NPR>5.  Recessed, grated floor drains required for equipment.</NPR><BRK/>
<BRK/>
<NPR>6.  Disconnect switches.</NPR><BRK/>
<BRK/>
<NPR>7.  Electrical chases and raceways and plumbing chases.</NPR><BRK/>
<BRK/>
<NPR>8.  Utility connections to building water, sanitary, electrical, and other utility 
systems.  Convenience outlets at point of use for plug-in equipment.</NPR><BRK/>
<BRK/>
<NPR>9.  All Contractor built-to-order items, per Food Service Equipment Schedule, 
shown and coordinated with the specifications.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Submit detail drawings as stated in section <SRF>11 05 40</SRF> - COMMON WORK RESULTS FOR FOOD SERVICE EQUIPMENT for food 
preparation equipment and related food processing equipment.  Drawings must be <MET> 1:50</MET><ENG> 1/4 inch</ENG> scale minimum.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>1.4   SUBMITTALS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL 
PROCEDURES and edit the following list to reflect only the submittals required 
for the project.  Submittals should be kept to the minimum required for adequate 
quality control.<BRK/>
<BRK/>
A “G” following a submittal item indicates that the submittal requires Government 
approval.  Some submittals are already marked with a “G”.  Only delete an existing 
“G” if the submittal item is not complex and can be reviewed through the Contractor’s 
Quality Control system.  Only add a “G” if the submittal is sufficiently important 
or complex in context of the project.<BRK/>
<BRK/>
For submittals requiring Government approval on Army projects, a code of up 
to three characters within the submittal tags may be used following the "G" 
designation to indicate the approving authority.  Codes for Army projects using 
the Resident Management System (RMS) are:  "AE" for Architect-Engineer; "DO" 
for District Office (Engineering Division or other organization in the District 
Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project 
Office.  Codes following the "G" typically are not used for Navy,  Air Force, 
and NASA projects.<BRK/>
<BRK/>
Choose the first bracketed item for Navy, Air Force and NASA projects, or choose 
the second bracketed item for Army projects.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Government approval is required for submittals with a "G" designation; submittals not having a "G" designation 
are [for Contractor Quality Control approval.][for information only.  When used, a designation following the 
"G" designation identifies the office that will review the submittal for the Government.]  Submit the following 
in accordance with Section <SRF>01 33 00</SRF> SUBMITTAL PROCEDURES:</TXT><BRK/>
<BRK/>
<LST><SUB>SD-01 Preconstruction Submittals</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Contractor's Field Verification Data</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<LST><SUB>SD-02 Shop Drawings</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Detail Drawings</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<ITM><SUB>Custom fabricated equipment</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<ITM><SUB>Installation Instructions and Diagrams</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<ITM>  Detail drawings, as specified,including insulation and utility requirements.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-03 Product Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>food preparation equipment</SUB></ITM><BRK/>
<BRK/>
<LST><SUB>SD-05 Design Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Manufacturer's descriptive and technical literature</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<LST><SUB>SD-06 Test Reports</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Manufacturer's Test Data</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<ITM><SUB>Field Test Reports</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<LST><SUB>SD-07 Certificates</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>NSF Certification</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<ITM><SUB>UL Certification</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<ITM><SUB>Energy Star Qualified</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<LST><SUB>SD-08 Manufacturer's Instructions</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Manufacturer's Instructions</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>] for shipping, handling, storage, installation, 
and start-up.</ITM><BRK/>
<BRK/></SPT>
<SPT><TTL>1.5   QUALITY ASSURANCE</TTL><BRK/>
<BRK/>
<TXT>Refer to section <SRF>11 05 40</SRF> - COMMON WORK RESULTS FOR FOOD SERVICE EQUIPMENT.</TXT><BRK/>
<BRK/>
<SPT><TTL>1.5.1   <HL3>Pre-Installation Conference</HL3></TTL><BRK/>
<BRK/>
<TXT>Thirty [_____] days prior to the commencement of work, notify the Contracting Officer that the following items 
are prepared and ready for review:</TXT><BRK/>
<BRK/>
<LST>a.  Shop Drawings, product data and installation instructions</LST><BRK/>
<BRK/>
<ITM>1.  <SUB>Detail Drawings</SUB></ITM><BRK/>
[<ITM>2.  <SUB>Custom fabricated equipment</SUB></ITM><BRK/>
<ITM>Submit custom fabricated equipment drawings after approval of food service equipment drawings.</ITM>]<BRK/>
<ITM>3.  <SUB>Installation Instructions and Diagrams</SUB></ITM><BRK/>
<BRK/>
<LST>b.  Product Data:</LST><BRK/>
<BRK/>
<ITM>1.  <SUB>Food preparation equipment</SUB></ITM><BRK/>
<BRK/>
<LST>c.  Design Data</LST><BRK/>
<BRK/>
<ITM>1.  <SUB>Manufacturer's descriptive and technical literature</SUB></ITM><BRK/>
<ITM><TST>2.  <SUB>Manufacturer's Test Data</SUB></TST></ITM><BRK/>
<ITM>3.  <SUB>Energy Star Qualified</SUB></ITM><BRK/>
<BRK/>
<LST>d.  Manufacturer's Instructions</LST><BRK/>
<BRK/>
<ITM>1.  <SUB>Manufacturer's Instructions</SUB> for shipping, handling, storage, installation, and start-up.</ITM><BRK/>
<BRK/></SPT>
</SPT></PRT><PRT><TTL>PART 2   PRODUCTS</TTL><BRK/>
<BRK/>
<SPT><TTL>2.1   MATERIALS</TTL><BRK/>
<BRK/>
<TXT>Food preparation equipment must conform to OSHA standards <RID>29 CFR 1910.144</RID>, <RID>29 CFR 1910.145</RID>, <RID>29 CFR 1910.212</RID>, <RID>
29 CFR 1910.306</RID>, <RID>NSF 2</RID>, <RID>NSF 59</RID>, <RID>NSF 8</RID>, <RID>NSF Product Listing</RID>, <RID>Energy Star</RID> and related UL standards as specified 
in section <SRF>11 05 40</SRF> - COMMON WORK RESULTS FOR FOOD SERVICE EQUIPMENT.</TXT><BRK/>
<BRK/>
<TXT>Floor areas adjacent to food preparation equipment point of operation, and working surfaces must conform to <RID>29 CFR 1910-SUBPART D</RID></TXT><BRK/>
<BRK/>
<TXT>Preparation equipment materials must conform to the requirements as stated in section <SRF>11 05 40</SRF> - COMMON WORK 
RESULTS FOR FOOD SERVICE EQUIPMENT.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2   LIST OF EQUIPMENT</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Edit the master "Food Service Equipment Schedule" in section 
<SRF>11 06 40.13</SRF> carefully; retain items of equipment used for the project.  The 
Equipment List is intended to be edited and included in the project Specification.  
List the information contained on the Equipment List on the Contract Drawings.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Submit detailed Food Service Equipment List as specified in section <SRF>11 06 40.13</SRF> - FOOD SERVICE EQUIPMENT SCHEDULE.  
Include submittal of <SUB>NSF Certification</SUB> and <SUB>UL Certification</SUB> for individual food preparation equipment components.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.3   CONSTRUCTION OF FABRICATED EQUIPMENT</TTL><BRK/>
<BRK/>
<TXT>Construction and finish of fabricated equipment must conform to the specifications as stated in section 
<SRF>11 05 40</SRF> - COMMON WORK RESULTS FOR FOOD SERVICE EQUIPMENT.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4   HAND SINKS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Handwashing sinks must be provided behind each serving line and in each 
food preparation area. Each handwashing sink must be provided with soap dispensers 
and either towel dispensers or electric hand dryers specified in Section 10 
28 13, TOILET ACCESSORIES.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>2.4.1   Sink Body</TTL><BRK/>
<BRK/>
<TXT>Provide sizes and mountings as indicated; provide in accord with requirements of <RID>NSF 2</RID>.  Provide in accord with <RID>
ASME A112.19.3</RID>.  Fabricate of<MET> 1.8 mm thick</MET><ENG> 14 gage</ENG> stainless steel.  Round vertical and horizontal corners with 
a radius of not less than<MET> 19 mm</MET><ENG> 0.75 inch</ENG>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4.2   Mounting</TTL><BRK/>
<BRK/>
[<SPT><TTL>2.4.2.1   Leg Mounting</TTL><BRK/>
<BRK/>
<TXT>Sink legs to be as specified for counters, except weld closed gussets to support channels.</TXT><BRK/>
<BRK/></SPT>
][<SPT><TTL>2.4.2.2   Wall Mounting</TTL><BRK/>
<BRK/>
<TXT>Provide stainless steel mounting brackets.</TXT><BRK/>
<BRK/></SPT>
][<SPT><TTL>2.4.2.3   Counter Mounting</TTL><BRK/>
<BRK/>
<TXT>Provide sink body [set in counter] [integral with counter].</TXT><BRK/>
<BRK/></SPT>
]</SPT><SPT><TTL>2.4.3   Faucets and Drain</TTL><BRK/>
<BRK/>
<TXT>Provide [splashback] [counter top] [and] [ledge] mounted [as indicated].  Provide gooseneck faucet spout , aerator, 
with two valves.  Provide nozzle with anti-splash device without hose thread.  Provide cleanout at location indicated 
on drawings.</TXT><BRK/>
<BRK/></SPT>
</SPT></PRT><PRT><TTL>PART 3   EXECUTION</TTL><BRK/>
<BRK/>
<SPT><TTL>3.1   INSTALLATION</TTL><BRK/>
<BRK/>
<TXT>Refer to section <SRF>11 05 40</SRF> - COMMON WORK RESULTS FOR FOOD SERVICE EQUIPMENT for detailed installation procedures, 
operation and maintenance manual requirements, training and project closeout procedures.  <TST>Include all food service 
preparation <SUB>Field Test Reports</SUB>.</TST></TXT><BRK/>
<BRK/></SPT>
</PRT>    <END/><BRK/></SEC>