<?xml version="1.0" encoding="windows-1252"?><SEC xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://si.ksc.nasa.gov/sidownloads/xml/specsintactSEC.xsd"><MTA NAME="SUBFORMAT" CONTENT="NEW"/><HDR><AST/><BRK/>
USACE / NAVFAC / AFCESA / NASA      UFGS-12 36 00.00 20 (April 2006)<BRK/>
                                    ------------------------------<BRK/>
Preparing Activity:  <PRA>NAVFAC</PRA>         Replacing without change<BRK/>
                                    UFGS-12301N (September 1999)<BRK/>
<BRK/>
<HL4>UNIFIED FACILITIES GUIDE SPECIFICATIONS</HL4><BRK/>
<BRK/>
<HL4>References are in agreement with UMRL dated January 2009</HL4><BRK/>
<AST/><BRK/></HDR>
<BRK/>
<SCN>SECTION 12 36 00.00 20</SCN><BRK/>
<BRK/>
<STL>MANUFACTURED VANITIES</STL><BRK/>
<DTE>04/06</DTE><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This guide specification covers the requirements for <SCP>vanities for Bachelor 
Enlisted Quarters (BEQ)</SCP>.<BRK/>
<BRK/>
Edit this guide specification for project specific requirements by adding, deleting, 
or revising text.  For bracketed items, choose applicable items(s) or insert 
appropriate information.<BRK/>
<BRK/>
Remove information and requirements not required in respective project, whether 
or not brackets are present.<BRK/>
<BRK/>
Comments and suggestions on this guide specification are welcome and should 
be directed to the technical proponent of the specification.  A listing of <URL HREF="http://65.204.17.188/report/ufgs.html">technical 
proponents</URL>, including their organization designation and telephone number, is 
on the Internet.<BRK/>
<BRK/>
Recommended changes to a UFGS should be submitted as a  <URL HREF="http://65.204.17.188/projnet/cms/public.html">Criteria Change Request 
(CCR)</URL>.</NPR><BRK/>
<AST/><BRK/></NTE>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Lavatories and wall base, if desired, must be specified in other sections.  
If the project requires custom wood millwork such as required in locations like 
the Marine Corps Air Station, Cherry Point and Marine Corps Base, Camp Lejeune, 
North Carolina, do not use this section.  Custom wood vanities require the designer 
to show elevations, sections, and details which clarify materials, thicknesses, 
size, finishes, and support framing on the contract drawings and use Section 
06200N FINISH CARPENTRY to specify the product.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<PRT><TTL>PART 1   GENERAL</TTL><BRK/>
<BRK/>
<SPT><TTL>1.1   REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This paragraph is used to list the publications cited in the text of 
the guide specification. The publications are referred to in the text by basic 
designation only and listed in this paragraph by organization, designation, 
date, and title.<BRK/>
 <BRK/>
Use the Reference Wizard's Check Reference feature when you add a RID outside 
of the Section's Reference Article to automatically place the reference in the 
Reference Article.  Also use the Reference Wizard's Check Reference feature 
to update the issue dates.<BRK/>
 <BRK/>
References not used in the text will automatically be deleted from this section 
of the project specification when you choose to reconcile references in the 
publish print process.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The publications listed below form a part of this specification to the extent referenced.  The publications are 
referred to within the text by the basic designation only.</TXT><BRK/>
<BRK/>
<REF><ORG>APA - THE ENGINEERED WOOD ASSOCIATION (APA)</ORG><BRK/><BRK/><RID>APA PS 1</RID><RTL>(1995) Voluntary Product Standard for Construction and Industrial Plywood</RTL><BRK/><BRK/></REF><REF><ORG>U.S. GENERAL SERVICES ADMINISTRATION (GSA)</ORG><BRK/><BRK/><RID>FED-STD-595</RID><RTL>(Rev B; Am 1) Colors Used in Government Procurement</RTL><BRK/><BRK/><RID>FS A-A-50565</RID><RTL>(Basic) Cabinet, Storage; Wardrobe, Three Drawer</RTL><BRK/><BRK/><RID>FS A-A-50567</RID><RTL>(Basic; Notice 1) Vanity; Cabinet (Wood or Wood and Steel)</RTL><BRK/><BRK/></REF></SPT><SPT><TTL>1.2   SUBMITTALS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL 
PROCEDURES and edit the following list to reflect only the submittals required 
for the project.  Submittals should be kept to the minimum required for adequate 
quality control.<BRK/>
<BRK/>
A “G” following a submittal item indicates that the submittal requires Government 
approval.  Some submittals are already marked with a “G”.  Only delete an existing 
“G” if the submittal item is not complex and can be reviewed through the Contractor’s 
Quality Control system.  Only add a “G” if the submittal is sufficiently important 
or complex in context of the project.<BRK/>
<BRK/>
For submittals requiring Government approval on Army projects, a code of up 
to three characters within the submittal tags may be used following the "G" 
designation to indicate the approving authority.  Codes for Army projects using 
the Resident Management System (RMS) are:  "AE" for Architect-Engineer; "DO" 
for District Office (Engineering Division or other organization in the District 
Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project 
Office.  Codes following the "G" typically are not used for Navy,  Air Force, 
and NASA projects.<BRK/>
<BRK/>
Choose the first bracketed item for Navy, Air Force and NASA projects, or choose 
the second bracketed item for Army projects.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Government approval is required for submittals with a "G" designation; submittals not having a "G" designation 
are [for Contractor Quality Control approval.][for information only.  When used, a designation following the 
"G" designation identifies the office that will review the submittal for the Government.]  The following shall 
be submitted in accordance with Section <SRF>01 33 00</SRF> SUBMITTAL PROCEDURES:</TXT><BRK/>
<BRK/>
<LST><SUB>SD-02 Shop Drawings</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Vanities</SUB>; [<SUB>G</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  Show configuration, materials, thicknesses, hardware, finishes, and colors of vanities for 
the project.</ITM><BRK/>
<BRK/></SPT>
<SPT><TTL>1.3   DELIVERY, STORAGE, AND HANDLING</TTL><BRK/>
<BRK/>
<TXT>Deliver vanities undamaged and store in a safe, dry, and clean location. Handle so as to prevent damage.</TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 2   PRODUCTS</TTL><BRK/>
<BRK/>
<SPT><TTL>2.1   <SUB>VANITIES</SUB></TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Insert type and size required.  Sizes listed are included in FS A-A-50567 
and should be used unless otherwise approved by the Engineering Field Division 
Code 04 in writing.  If other sizes are required, determine whether modification 
of door/intermediate panel configuration is required to maintain proper door 
size and structural support.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT><RID>FS A-A-50567</RID>, [Type I (single lavatory, double doors), Size [A (<MET>750 mm</MET><ENG>30 inches</ENG> wide)] [B (<MET>900 mm</MET><ENG>36 inches</ENG> wide)] 
[C (<MET>1050 mm</MET><ENG>42 inches</ENG> wide)] [D (<MET>1200 mm</MET><ENG>48 inches</ENG> wide)]] [Type II (double lavatory, two sets of double doors), 
Size A (<MET>1500 mm</MET><ENG>60 inches</ENG> wide)] [Type [_____], except size shall be [as indicated] [[_____]<MET> mm</MET><ENG> inches</ENG> wide]], 
and except as specified herein.  Wood construction shall be used.  Particleboard shall not be used.  Countertop, 
doors, and all wood panels shall be<MET> 20 mm</MET><ENG> 3/4 inch</ENG> plywood, <RID>APA PS 1</RID>, Exterior Type, Grade A-A.  Chromium-plated 
brass pulls or aluminum pulls and chromium-plated, spring-loaded, self-closing, adjustable, European type hinges 
may be used in lieu of pulls, hinges, and magnetic catches specified in <RID>FS A-A-50567</RID>.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.1.1   Quantity</TTL><BRK/>
<BRK/>
<TXT>[_____] [As indicated].</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.2   FINISHES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Since a wood or steel constructed vanity is the Contractor's option, 
specify finish, pattern, and color for laminated plastic for both and a paint 
color for steel.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Five-digit designations refer to <RID>FED-STD-595</RID>.</TXT><BRK/>
<BRK/>
<SPT><TTL>2.2.1   Exposed Surfaces</TTL><BRK/>
<BRK/>
<TXT>Exterior of doors and exposed surfaces of cabinet body shall be decorative laminated plastic of color and pattern 
[indicated] [specified].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.2.2   Concealed Surfaces</TTL><BRK/>
<BRK/>
<TXT>Interior of doors and cabinet body, and concealed exterior surfaces of cabinet body, shall be nondecorative laminated 
plastic.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>2.3   END CURBS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Delete this paragraph if end curbs are not required.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Provide end curbs to match back splash where end of countertop abuts a wall.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.4   DRAWERS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Delete this paragraph if drawers are not required.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Where drawers are indicated in vanities, comply with <RID>FS A-A-50565</RID> for drawers, drawer slides, and slide supports.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.5   SOURCE QUALITY CONTROL</TTL><BRK/>
<BRK/>
<TXT>Sampling and Examination:  <RID>FS A-A-50567</RID>.</TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 3   EXECUTION</TTL><BRK/>
<BRK/>
<SPT><TTL>3.1   INSTALLATION</TTL><BRK/>
<BRK/>
<SPT><TTL>3.1.1   Final Assembly</TTL><BRK/>
<BRK/>
<TXT>Distribute vanities to rooms [as indicated] [as directed].  Uncrate, assemble, adjust as necessary, and place 
as specified or indicated, complete with accessories and hardware.  Position vanities [as indicated] [as directed].</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.1.2   Fastening</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Ensure that work referred to is actually specified in the referenced 
sections.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Fasten wood vanities as specified in <RID>FS A-A-50567</RID>.  Fasten steel vanities through the holes in vanity back flanges.  
Fasteners shall be appropriate for use with the wall construction.  Seal joint between back splash and wall and 
between end curb and wall as specified in Section <SRF>07 92 00</SRF> JOINT SEALANTS.</TXT><BRK/>
<BRK/></SPT>
</SPT></PRT>    <END/><BRK/></SEC>