<?xml version="1.0" encoding="windows-1252"?><SEC xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://si.ksc.nasa.gov/sidownloads/xml/specsintactSEC.xsd"><MTA NAME="SUBFORMAT" CONTENT="NEW"/><BRK/>
<HDR><AST/><BRK/>
USACE / NAVFAC / AFCESA / NASA              UFGS-31 31 16.21 (August 2008)<BRK/>
                                            ------------------------------<BRK/>
Preparing Activity:  <PRA>USACE</PRA>                  Superseding<BRK/>
                                            UFGS-31 31 16.21 (April 2006)<BRK/>
<BRK/>
<HL4>UNIFIED FACILITIES GUIDE SPECIFICATIONS</HL4><BRK/>
<BRK/>
<HL4>References are in agreement with UMRL dated January 2009</HL4><BRK/>
<AST/><BRK/></HDR>
<BRK/>
<SCN>SECTION 31 31 16.21</SCN><BRK/>
<BRK/>
<STL>MESH TERMITE BARRIER</STL><BRK/>
<DTE>08/08</DTE><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This guide specification covers the requirements for <SCP>mesh termite barrier 
for termite control.  This UFGS is not for a soil treatment</SCP>.<BRK/>
<BRK/>
Edit this guide specification for project specific requirements by adding, deleting, 
or revising text.  For bracketed items, choose applicable items(s) or insert 
appropriate information.<BRK/>
<BRK/>
Remove information and requirements not required in respective project, whether 
or not brackets are present.<BRK/>
<BRK/>
Comments and suggestions on this guide specification are welcome and should 
be directed to the technical proponent of the specification.  A listing of <URL HREF="http://65.204.17.188/report/ufgs.html">technical 
proponents</URL>, including their organization designation and telephone number, is 
on the Internet.<BRK/>
<BRK/>
Recommended changes to a UFGS should be submitted as a  <URL HREF="http://65.204.17.188/projnet/cms/public.html">Criteria Change Request 
(CCR)</URL>.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<PRT><TTL>PART 1   GENERAL</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Termite infestation exists throughout the United States and overseas 
areas with the exception of Alaska.  Mesh termite barriers can be prescribed 
for installation at all sites where termites are likely to establish colonies 
and make concealed access to wood construction, when it is deemed appropriate 
and cost effective.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>1.1   REFERENCES</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  This paragraph is used to list the publications cited in the text of 
the guide specification.  The publications are referred to in the text by basic 
designation only and listed in this paragraph by organization, designation, 
date, and title.<BRK/>
<BRK/>
Use the Reference Wizard's Check Reference feature when you add a RID outside 
of the Section's Reference Article to automatically place the reference in the 
Reference Article.  Also use the Reference Wizard's Check Reference feature 
to update the issue dates.<BRK/>
<BRK/>
References not used in the text will automatically be deleted from this section 
of the project specification when you choose to reconcile references in the 
publish print process.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>The publications listed below form a part of this specification to the extent referenced.  The publications are 
referred to within the text by the basic designation only.</TXT><BRK/>
<BRK/>
<REF><ORG>ASTM INTERNATIONAL (ASTM)</ORG><BRK/><BRK/><RID>ASTM A 478</RID><RTL>(1997; R 2008) Standard Specification for Chromium-Nickel Stainless Steel Weaving and Knitting Wire</RTL><BRK/><BRK/><RID>ASTM A 580/A 580M</RID><RTL>(2008) Standard Specification for Stainless Steel Wire</RTL><BRK/><BRK/></REF></SPT><SPT><TTL>1.2   SYSTEM DESCRIPTION</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  The mesh physically prevents termites from entering the building.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Place the stainless steel mesh across all openings to the building (shrinkage cracks in concrete slabs and built 
penetrations in slabs and walls that termites may use).  The mesh shall be bonded to the material surrounding 
the opening using bonding cement, when directed by the Contracting Officer, after determing that a quality bond 
can be obtained.  A correct and complete installation with no gaps, penetrations or damage to the mesh is essential 
to achieve and effective barrier.  <SUB>System Installers</SUB> shall be trained in the behavior of termites and the installation 
techniques of the mesh barrier.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.3   SUBMITTALS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Review submittal description (SD) definitions in Section <SRF>01 33 00</SRF> SUBMITTAL 
PROCEDURES and edit the following list to reflect only the submittals required 
for the project.  Submittals should be kept to the minimum required for adequate 
quality control.<BRK/>
<BRK/>
A “G” following a submittal item indicates that the submittal requires Government 
approval.  Some submittals are already marked with a “G”.  Only delete an existing 
“G” if the submittal item is not complex and can be reviewed through the Contractor’s 
Quality Control system.  Only add a “G” if the submittal is sufficiently important 
or complex in context of the project.<BRK/>
<BRK/>
For submittals requiring Government approval on Army projects, a code of up 
to three characters within the submittal tags may be used following the "G" 
designation to indicate the approving authority.  Codes for Army projects using 
the Resident Management System (RMS) are:  "AE" for Architect-Engineer; "DO" 
for District Office (Engineering Division or other organization in the District 
Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project 
Office.  Codes following the "G" typically are not used for Navy, Air Force, 
and NASA projects.<BRK/>
<BRK/>
Choose the first bracketed item for Navy, Air Force and NASA projects, or choose 
the second bracketed item for Army projects.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<TXT>Government approval is required for submittals with a "G" designation; submittals not having a "G" designation 
are for [Contractor Quality Control approval.][information only.  When used, a designation following the "G" 
designation identifies the office that will review the submittal for the Government.]  Submit the following in 
accordance with Section <SRF>01 33 00</SRF> SUBMITTAL PROCEDURES:</TXT><BRK/>
<BRK/>
<LST><SUB>SD-02 Shop Drawings</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Installation</SUB>[; <SUB>G</SUB>][; <SUB>G, [_____]</SUB>]</ITM><BRK/>
<BRK/>
<ITM>  Shop drawings of mesh installation at perimeter, joint, and penetration conditions.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-03 Product Data</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Materials</SUB></ITM><BRK/>
<BRK/>
<ITM>  Descriptive data for materials used in this work.</ITM><BRK/>
<BRK/>
<ITM><SUB>Barrier Mesh</SUB></ITM><BRK/>
<BRK/>
  <ITM>  Manufacturer's label and Material Safety Data Sheet (MSDS) proposed for use.</ITM><BRK/>
<BRK/>
<ITM><SUB>Manufacturer's guidance</SUB></ITM><BRK/>
<BRK/>
<ITM>  Manufacturer's installation instruction manual.</ITM><BRK/>
<BRK/>
<ITM><SUB>Visual Inspection Guide</SUB></ITM><BRK/>
<BRK/>
<ITM>  Manufacturer's visual inspection guide.</ITM><BRK/>
<BRK/>
<ITM><SUB>Site Verification</SUB></ITM><BRK/>
<BRK/>
<ITM>  Written verification that site conditions are as required and other site work will not disturb 
the installation.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-04 Samples</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>Barrier Mesh</SUB></ITM><BRK/>
<BRK/>
<ITM>  Samples of stainless steel mesh to be used in this work, <MET>102 x 102 mm</MET><ENG> 4 x 4 inches</ENG>.</ITM><BRK/>
<BRK/>
<LST><SUB>SD-07 Certificates</SUB></LST><BRK/>
<BRK/>
<ITM><SUB>System Installers</SUB></ITM><BRK/>
<BRK/>
<ITM>  Qualifications of installer's personnel, level of accreditation and the effective time period 
of the accreditation level.</ITM><BRK/>
<BRK/>
<ITM><SUB>Materials</SUB></ITM><BRK/>
<BRK/>
<ITM>  Written verification from the manufacturer that the material furnished meets the specified 
requirements.</ITM><BRK/>
<BRK/></SPT>
<SPT><TTL>1.4   DELIVERY, STORAGE, AND HANDLING</TTL><BRK/>
<BRK/>
<TXT>Deliver materials to the site in original, unbroken packaging and containers, with original labels in place.  
The bonding cement shall be in the original sealed containers with all labels intact to include any EPA designation.  
Store materials in conformance with manufacturer's recommendations.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>1.5   WARRANTY</TTL><BRK/>
<BRK/>
<TXT>Provide a minimum 1-year warranty.</TXT><BRK/>
<BRK/></SPT>
</PRT><PRT><TTL>PART 2   PRODUCTS</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  Check with local agencies to determine the local building code requirements 
and specifications to ensure conformance where required.</NPR><BRK/>
<AST/><BRK/></NTE>
<SPT><TTL>2.1   <SUB>MATERIALS</SUB></TTL><BRK/>
<BRK/>
<SPT><TTL>2.1.1   Asbestos Prohibition</TTL><BRK/>
<BRK/>
<TXT>No asbestos containing materials or equipment are permitted at the job site.  Ensure that materials proposed 
for the project are asbestos free.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.2   <SUB>Barrier Mesh</SUB></TTL><BRK/>
<BRK/>
<TXT>Stainless steel mesh shall conform to <RID>ASTM A 478</RID> and <RID>ASTM A 580/A 580M</RID>, Type A1AA marine grade 316 stainless 
steel mesh of<MET> 0.18 mm</MET><ENG> 0.007 inch</ENG> diameter wire with mesh openings of<MET> 0.66 x 0.45 mm</MET><ENG> 0.026 x 0.018 inches</ENG>.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>2.1.3   Accessories</TTL><BRK/>
<BRK/>
<TXT>Parging adhesives, bonding cement, clamps, ties, and other accessories as recommended by the manufacturer.</TXT><BRK/>
<BRK/></SPT>
</SPT></PRT><PRT><TTL>PART 3   EXECUTION</TTL><BRK/>
<NTE><BRK/>
<AST/><BRK/>
<NPR>NOTE:  The stainless steel mesh must be installed in a manner to provide maximum 
protection to the dwelling.  The material provides a physical barrier to the 
termites, thus, preventing entry.  A range of techniques and material widths 
may be required to meet site conditions.  The designer is required to determine 
the extent of openings to be covered to provide quantity estimates for the material 
installed.</NPR><BRK/>
<AST/><BRK/></NTE>
<BRK/>
<SPT><TTL>3.1   <SUB>SITE VERIFICATION</SUB></TTL><BRK/>
<BRK/>
<SPT><TTL>3.1.1   Site Preparation</TTL><BRK/>
<BRK/>
<TXT>Site preparation shall be in accordance with Sections <SRF>31 11 00</SRF> CLEARING AND GRUBBING, <SRF>31 00 00</SRF> EARTHWORK, 
<SRF>32 92 19</SRF> SEEDING, <SRF>32 92 23</SRF> SODDING, <SRF>32 92 26</SRF> SPRIGGING, AND <SRF>32 93 00</SRF> EXTERIOR PLANTS.  Work related to final 
grades, landscape plantings, foundations, or any other alterations to finished construction that might alter 
the condition of the site, shall be coordinated with this specification.  Do not proceed until any unsatisfactory 
conditions detrimental to timely and proper completion of the work have been corrected.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.1.2   Ground Preparation</TTL><BRK/>
<BRK/>
<TXT>Eliminate termite food sources by removing debris from the clearing and grubbing operations and construction 
wood scraps such as ground stakes, form boards, and scrap lumber from the work area, before installing the mesh 
barrier.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.1.3   Verification</TTL><BRK/>
<BRK/>
<TXT>Before installing the mesh, verify that final grades are as indicated and smooth grading has been completed.  
Soil particles in the work area shall be finely graded with particles no larger than<MET> 25 mm</MET><ENG> 1 inch</ENG> and compacted 
to eliminate soil movement to the greatest degree.  The condition of the site shall meet the manufacturer's recommendations 
prior to installing the mesh barrier.</TXT><BRK/>
<BRK/></SPT>
</SPT><SPT><TTL>3.2   <SUB>INSTALLATION</SUB></TTL><BRK/>
<BRK/>
<TXT>Install the mesh barrier in accordance with the manufacturer's recommendations.  The stainless steel mesh shall 
be lap-jointed<MET> 10 to 15 mm</MET><ENG> 0.39 to 0.59 inch</ENG>.  The joint may be strengthened by using bonding cement a minimum 
distance of<MET> 500 to 1000 mm</MET><ENG> 20 to 40 inches</ENG> along the joint.  Penetrations and shrinkage cracks through concrete 
slabs shall be sealed as recommended.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.3   PROTECTION</TTL><BRK/>
<BRK/>
<TXT>The installed mesh shall be protected as required or directed.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.4   <SUB>VISUAL INSPECTION GUIDE</SUB></TTL><BRK/>
<BRK/>
<TXT>To maintain resistance to termites, the system shall be complete and not disturbed, penetrated or damaged during 
the remaining contract time period.  The installer shall provide <SUB>manufacturer's guidance</SUB> for performing a visual 
assessment of the installed mesh barrier to ensure the mesh barrier provides the designed termite physical barrier.</TXT><BRK/>
<BRK/></SPT>
<SPT><TTL>3.5   REPAIRS</TTL><BRK/>
<BRK/>
<TXT>If live subterranean termite entry is discovered during the warranty period, provide an evaluation of the site 
and repair the installed mesh barrier and any damage occurred, as required.</TXT><BRK/>
<BRK/></SPT>
</PRT>    <END/><BRK/></SEC>