WARNING: Do Not Modify This File! Check 5.3 Data File CONTROL 1 ( code = CEZ_IECC2000 use energy = FALSE use gross areas = TRUE version = 5.3 ) LOCATION 1 ( use location file = TRUE location file type = MEC_CITIES state = Louisiana city = Covington ) BUILDING 1 ( user data = 0 bldg use type = WHOLE_BLDG req aspect ratio = 2.00 prop aspect ratio = 2.00 conditioning = HEATING_AND_COOLING ) ROOF 2 ( type = METAL_ROOF_W_THERMAL_BREAK user data = 0 list position = 1 description = Metal Roof with Thermal Blocks assembly type = Roof 1 parent number = 0 cavity rvalue = 23.00 continuous rvalue = 19.00 prop uvalue = default orientation = UNSPECIFIED_ORIENTATION cav rvalue constraints = 0 11 13 19 25 30 AND cont rvalue constraints = 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 AND gross area = 1500.000 net area = 1500.000 width = 0.000 width string = height = 0.000 height string = quantity = 1 ) AG_WALL 3 ( type = METAL_FRAME_16_AG_WALL heat capacity = 1.00 furring type = NO_FURRING next to uncond space = 0 insulation position = INTEGRAL user data = 0 list position = 2 description = Metal Frame, 16" o.c. assembly type = Exterior Wall 1 parent number = 0 cavity rvalue = 19.00 continuous rvalue = 15.00 prop uvalue = default orientation = UNSPECIFIED_ORIENTATION daylight credit = 0.000 cav rvalue constraints = 0 7 11 13 19 AND cont rvalue constraints = 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 AND gross area = 1500.000 net area = 1385.000 width = 0.000 width string = height = 0.000 height string = quantity = 1 ) WINDOW 4 ( prop projection factor = 0.18 is glass door = TRUE type = OTHER_GLAZING frame type = OTHER_FRAME solar type = TINTED vlt = 0.000 prop shgc = default prop sc = default user data = 0 list position = 3 description = Glass assembly type = Door 1 parent number = 3 prop uvalue = 0.024000 orientation = UNSPECIFIED_ORIENTATION daylight credit = 0.000 gross area = 40.000 net area = 40.000 width = 0.000 width string = height = 0.000 height string = quantity = 1 ) WINDOW 5 ( prop projection factor = default is glass door = TRUE type = OTHER_GLAZING frame type = OTHER_FRAME solar type = TINTED vlt = 0.000 prop shgc = default prop sc = default user data = 0 list position = 4 description = Glass assembly type = window parent number = 3 prop uvalue = 0.019000 orientation = UNSPECIFIED_ORIENTATION daylight credit = 0.000 gross area = 75.000 net area = 75.000 width = 0.000 width string = height = 0.000 height string = quantity = 1 ) SLAB 6 ( type = UNHEATED_SLAB depth of insulation= 0.00 insulation position = NO_INSULATION user data = 0 list position = 5 description = Unheated, No Insulation assembly type = Slab 1 parent number = 0 prop uvalue = default orientation = UNSPECIFIED_ORIENTATION gross area = 1500.000 net area = 1500.000 width = 0.000 width string = height = 0.000 height string = quantity = 1 ) FIXTURE 1 ( lighting type = LONG_FLUOR type of fixture = 2x4 description = 2x4 surface mt fixture type = T8 / T12 Fluorescent 1 parent number = 0 list position = 1 lamp ballast description = 48" T12 40W lamp type = 48" T12 40W ballast = MAGNETIC number of lamps = 2 lamp wattage = 0 power adjustment factor = 0.000 paf desc = None fixture wattage = 40 power allowance = 0.000 quantity = 10 ) FIXTURE 2 ( lighting type = INCANDESCENT type of fixture = ceiling description = Recessed can light fixture type = Ceiling mounted fixture parent number = 0 list position = 2 lamp ballast description = Incandescent 100W lamp type = Incandescent 100W ballast = UNSPECIFIED_BALLAST number of lamps = 1 lamp wattage = 0 power adjustment factor = 0.000 paf desc = None fixture wattage = 100 power allowance = 0.000 quantity = 3 ) HVAC SYSTEM 2 ( description = Heating: Unit Heater, Electric / Cooling: Packaged Terminal Unit, Capacity <65 kBtu/h, Evaporatively Cooled Condenser system type = HVAC System 2 quantity = 1 list position = 1 heating equipment = Unit Heater cooling equipment = Packaged Terminal Unit heat pump = Packaged Terminal zone = Single Zone perimeter system = FALSE heating capacity = 0.0000 fuel = ELECTRIC hp condenser = Air-Cooled distribution = Single Duct vav box = FALSE fan powered vav = FALSE vav mixing box = FALSE cv mixing box = FALSE reheat recool coil = FALSE electric reheat = FALSE hydronic reheat = FALSE steam reheat = FALSE condenser = Evaporatively Cooled cooling capacity = <65 kBtu/h economizer = Air Economizer economizer exception = Unknown fan control = Unknown supply fan hp over 25 = FALSE supply static over 3 = FALSE return fan hp over 25 = FALSE ) PROJECT 1 ( name = "Linda Gambino Robert St. Slidell, LA. 70458 " ) PROJECT 1 ( preparer = "Emmett Dammon" ) PROJECT 1 ( designer = "Dammon Engineering Suite 100 Old Spanish Trail Slidell, La. 70458 Slidell, La. 70458" ) WHOLE BLDG USE 3 ( whole bldg type = Storage, Industrial and Commercial power density = 0.6 internal load = 0.1 floor area = 1500 valid whole bldg type = TRUE )